7. Pre-Operation Checklists / Maintenance Checklists
After wiring, mounting and beam alignment are done, check the operation of the F3SJ-B-02TS.
Pre-Operation Checklists
After installation, the highest level administrator must use the following checklist to verify the operation, plac-
ing a check mark in each of the boxes.
■
Checklists
- Installation Condition Check
□
The machine itself does not prevent the operation of safety functions such as stopping.
□
The hazardous part of a machine cannot be reached without passing through the detection zone of the
F3SJ-B-02TS.
□
The system is configured so that the F3SJ-B-02TS can always detect a worker who is working in the haz-
ardous zone.
□
The interlock reset switch is installed in a location that provides a clear view of the entire hazardous zone
and it cannot be activated from within the hazardous zone.
□
Safety distance has been calculated. Calculated distance: S = ( ) mm
□
The actual distance is equal to or greater than the calculated distance. Actual distance = ( ) mm
□
Reflective surfaces are not installed in prohibited zones.
□
Not installed in a reflective configuration.
□
When muting function is used, a muting sensor must be installed so that muting state should not occur
when a human body enters a detection zone of F3SJ-B-02TS by mistake.
□
When muting function is used, a muting sensor must be installed so that muting state should not occur
when a human body enters a hazardous zone of a machine.
□
When muting function is used, muting state can be checked from where a worker operates or adjust the
machine.
□
A muting sensor consists of two independent devices.
□
Not used in flammable or explosive atmosphere.
- Wiring Check Before Power Is Turned ON
□
Sharing the power supply with other devices may cause the F3SJ-B-02TS to be affected by noise or volt-
age drop. It is recommended that this safety component use a dedicated power supply but do not share
with other devices.
□
The power supply unit provides 24 VDC while complying with the EMC Directive, Low Voltage Directive,
output holding specification.
□
The power supply polarity is not connected in reverse.
□
Emitter/receiver cables are properly connected to the respective emitters/receivers.
□
Double insulation is provided between input/output and hazardous voltage (commercial power source,
etc.).
□
Outputs are not short-circuited to +24 V line.
□
Loads are not connected to the +24 V line.
□
All lines are not connected to commercial power source.
□
Model of emitter and receiver must be the same.
□
When two or more sets of F3SJ-B-02TSs are used, they are series-connected or mutual interference pre-
vention measures are taken.
□
When two or more sets of F3SJ-B-02TSs are used in series connection, sensors other than the F3SJ-B-
02TS must not be connected.
□
A secondary sensor farthest from its power supply has either of the following:
• Cap
• Key cap for muting
□
Neither connector nor bracket must be loose.
□
Auxiliary output must not be used as safety output.
□
Power supply's 0 V must be grounded.
□
Wiring must not be bent, cracked, nor damaged.
-Operation Check While the Machine Is Stopped
□
The test rod is not deformed.
Mounting/Beam Alignment
Wiring
Function Selection
Pre-Operation Checklist /
Maintenance Checklists
Summary of Contents for Sti F3SJ-B P25-02TS Series
Page 15: ...F3SJ B P25 02TS OMRON Corporation 2017 2018 All Rights Reserved Original instructions...
Page 17: ...2 F3SJ B 02TS 2 3 3 4 5 10...
Page 18: ...3 F3SJ B 02TS 4 F3SJ B 02TS...
Page 22: ...7 F3SJ B 02TS 6 2 1 2 6 1...
Page 23: ...8 F3SJ B 02TS 3 4...
Page 24: ...9 F3SJ B 02TS 5 F39 LJB2 30 6 M3 8 M3 18 1 EMITTER RECEIVER...