Overview and Specifications
E
Indicator Display Patterns
Internal Indicator for Basic System
Shown below are indication statuses of F3SJ's internal indicator when you purchased.
No.
Indicators
ON/
Blinking
Description
1
Incident light level
indicator
LEVEL-1 to 5
ON
Indication status of LEVEL-1 to 5 shows the incident light level
status of the F3SJ.
2
Error mode indicator
ERROR-A to C ON/
Blinking
Turns ON or blinks only when the F3SJ enters lockout, and the
cause of the error is indicated by the status of ERROR-A to C
indicators.When F3SJ are series-connected, the error mode
indicator lamps turn ON or blink according to the details of each
error. Affix the error mode label (included) near the F3SJ to
allow for quick troubleshooting when errors occur. For details of
the error mode, see "Chapter 7 Troubleshooting".
3
Power indicator
POWER
ON
Turns ON while the power is ON.
Blinking Blinks during maintenance status.
4
Interlock indicator
INTLK
ON
Turns ON when F3SJ is in interlock state.
Blinking Blinks when in lockout.
5
External device
monitoring indicator
EDM
ON
Turns ON when an input is given to external device monitoring
input.
6
Blanking/Test indicator
BLANKING/
TEST
ON
Turns ON when the blanking function and warning zone function
are enabled.
Blinking Blinks when external test is being performed.
4. Interlock indicator (Yellow)
3. Power indicator (Green)
2. Error mode
indicator
1. Incident light level
indicator
EMITTER
LEVEL
POWER
ERROR
ERROR
INTLK
EDM
Blanking
(TEST)
5
4
3
2
1
C
B
A
5
4
3
2
1
C
B
A
RECEIVER
LEVEL
OFF
ON
*1
LEVEL-5 (Green)
LEVEL-1 (Orange)
LEVEL-2 (Orange)
LEVEL-3 (Orange)
LEVEL-4 (Green)
ERROR-
C (Red)
ERROR-B (Red)
ERROR-A (Red)
LEVEL-1 (Orange)
LEVEL-2 (Orange)
LEVEL-3 (Orange)
LEVEL-4 (Green)
LEVEL-5 (Green)
ERROR-B (Red)
ERROR-A (Red)
ERROR-C (Red)
1. Incident light
level indicator
2. Error mode
indicator
8. ON-state indicator (Green)
7. OFF-state indicator (Red)
Emitter
Receiver
5. External device monitoring indicator (Green)
[Muting input 1 indicator]
6. Blanking/Test indicator(Green)
[Muting input 2 indicator]
9. Not used (Green)
[Muting error indicator]
10. Not used (Green)
[Blanking/Test indicator]
A set of square brackets, [ ], indicates
name of an indicator under muting system.
*1 This label comes with the F39-CN6 key
cap for muting. Affix this label when a
keycap is used.