171
F3SJ-A
User’s Manual
Ch
apt
e
r
5
Wir
ing
Ex
amples
Input/Output Circuit and Applications
E
Connecting 4 Muting Sensors
• Attaching a key cap for muting (F39-CN6) enables the muting function to be used
Attaching the key cap for muting (F39-CN6) p.36
Wiring When External Device Monitoring Function Is Not Required p.41
Using the setting tool enables the use of start interlock and restart interlock.
F3SJ
Workpiece
KM1
KM2
S1
S2
M
KM1
KM2
OUT
PLC
IN
KM3
+DC24V
0 V
E1
A1
B1
A2
B2
KM1 KM2
*: Output operation mode of auxiliary output 1 is "safety output information/reverse enabled" (initial setting)
F39-JC A-L
F39-JC A-D
Emitter
Receiver
- Auto reset mode
- Using external device monitoring function
Muting lamp
(external indicator)
Communication
line (+) (Grey)
Communication
line (-) (Pink)
Shield
0V (Blue)
Muting input 2 (Red)
T
est input (Green)
Reset input (Y
ellow)
Muting input 1 (White)
+24V (Brown)
+24V (Brown)
External device monitoring input (Red)
Auxiliary output 1 (Y
ellow)
Safety
output 1 (Green)
Safety
output 2 (White)
0V (Blue)
Shield
S1
:External test switch
(connect to 0V if a switch is not required)
S2
:Lockout reset switch
(connect to 24V if a switch is not required)
KM1, KM2 :Safety relay with forcibly-guided contact (G7SA) or
magnetic contactor
KM3
:Solid state contactor (G3J)
M :3-phase
motor
E1
:24VDC power supply (S82K)
PLC :Programmable
controller
(Used for monitoring -- not related to safety system)
A1,B1,A2,B2 : Muting sensor (Retro-reflective photoelectric
sensor (E3Z-R81))
Unblocked
Blocked
Muting input 1
Muting input 2
F3SJ Safety output
A1 Safety output
B1 Safety output
A2 Safety output
B2 Safety output
KM1,KM2 N.O. contact
KM1,KM2 N.C. contact
PLC input (*)
PLC output
(PNP output)
Reflector
Muting sensor
Two-wire type sensor cannot be used.
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪