background image

No.16S061-09 

STC-S133 Series 
Specifications 

1/55 

TV Format 

0.65M Small Camera 

STC-S133 series 

[NTSC Output] 

STC-S133N 

(No lens mount type, Dual Pass Filter) 

STC-S133N

NF 

(No IR cut filter type, Non-Dual Pass Filter) 

STC-S133N

L   

(M12 fixed lens mount type, Dual Pass Filter) 

STC-S133N

CS 

(CS mount type)

STC-S133N

LS 

(M12 fixed lens mount type, Holder Short 

Dual Pass Filter) 

  [PAL Output] 

STC-S133P 

(No lens mount type, Dual Pass Filter) 

STC-S133P

NF 

(No IR cut filter type, Non-Dual Pass Filter) 

STC-S133P

L   

(M12 fixed lens mount type, Dual Pass Filter) 

STC-S133P

CS 

(CS mount type, Dual Pass Filter)

STC-S133P

LS 

(M12 fixed lens mount type, Holder Short 

Dual Pass Filter) 

Product Specifications 

Aegis Electronic Group, Inc.

For more information please contact Aegis Electronic Group, Inc. *(888)687-6877 *[email protected] *http://www.aegiselect.com

(888)687-6877

Summary of Contents for STC-S133 Series

Page 1: ...t type Holder Short Dual Pass Filter PAL Output STC S133P No lens mount type Dual Pass Filter STC S133P NF No IR cut filter type Non Dual Pass Filter STC S133P L M12 fixed lens mount type Dual Pass Filter STC S133P CS CS mount type Dual Pass Filter STC S133P LS M12 fixed lens mount type Holder Short Dual Pass Filter Product Specifications A e g i s E l e c t r o n i c G r o u p I n c For more info...

Page 2: ...ifications 12 Power input video output UART communication connector 12 OSD menu control 13 5 Dimensions 15 5 1 STC S133N STC S133P 15 5 2 STC S133N NF STC S133P NF 15 5 3 STC S133N L STC S133P L 16 5 4 STC S133N LS STC S133P LS 16 5 5 STC S133N CS STC S133P CS 17 5 6 RC S133 18 6 Communication control software users guide 19 6 1 Requirement software and JIG tool 19 6 2 Connecting configuration 19 ...

Page 3: ...e Tab 41 Analog Tab 41 Blemish Pixel Tab 42 Info Tab 42 Field Table 42 One Shot 43 7 Camera setting by the OSD 44 7 1 The camera setting change by the on screen display 44 The camera setting change by the controller that connects to CN1 44 OSD operation by the communication software 44 OSD menu 45 SETUP MENU 45 SHUTTER AGC 46 WHITE BAL 47 BACK LIGHT 48 PICT ADJUST 49 DEFOG 49 WDR ATR 50 Day Night ...

Page 4: ... S133 Series Specifications 4 55 8 Revisions 54 A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www aegiselect com ...

Page 5: ...n or instruction Environment condition Warning Do not use flammable or explosiveness atmospheres This will cause of personal injury or fire Do not use for safety for human body related usage This camera is designed for use do not harm human body immediately if by any chance the camera has malfunction Caution Use and store under specified environmental conditions Vibration shock temperature humidit...

Page 6: ...caused by malfunction Do not put combustibles near the camera This will cause of fire Do not use without usage that is specified in the specifications for this camera This will cause of personal injury or malfunction Do not push metals including screw driver into radiation holes This will cause of electrification or malfunction Caution Do not push contamination into opening of the camera This will...

Page 7: ...ear due to the sensor characteristics Use below recommend materials or equivalent materials to clean the surface of glass Air dust Non Freon air duster NAKABAYASHI Co LTD Alcohol Propan 2 ol SAN EI KAKO Co LTD Non woven nikowipe clean room NKB Use a soft cloth to clean the camera 2 Warranty Warranty period One year after delivery However the camera had malfunction with camera uses correctly In bel...

Page 8: ...ens vignetting and distortion correction Shading correction Configurable many parameters through the control software Wide dynamic range ATR EX and defog function Pixel blemish correction OSCD On Screen Character Display is available for the parameters configuration 3 2 Naming method STC S133x xx Back Panel N NTSC Output P PAL Output Suffix Space No lens mount type NF No IR cut filter type L M12 f...

Page 9: ...rol software KSACtrl 5 Remote Controller RC S133 Connection diagram Camera configuration via PC 1 2 3 and 4 are required As for the procedure please refer to another chapter Camera configuration via OSD 1 2 4 and 5 are required As for the procedure please refer to another chapter 2 JIG USB2 4 KSAF003 1 UN310 1210 5 RC S133 3 KSACtrl SW Right side A e g i s E l e c t r o n i c G r o u p I n c For m...

Page 10: ...htness correction Noise reduction 2D Negative Positive image False color correction Communication UART communication UART 3 3V Communication baud rate 230 400 bps 115 200 bps 57 600 bps 38 400 bps 28 800 bps 19 200 bps 14 400 bps 9 600 bps Default 115 200 bps All camera functions are configurable by the UART communication OSD Controllable by the remote control or UART communication Power Input vol...

Page 11: ...Filter Spectral Sensitivity Characteristics 0 10 20 30 40 50 60 70 80 90 100 350 450 550 650 750 850 950 1050 1150 Transmittance A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www aegiselect com ...

Page 12: ...nce lock input 1 8 GND GND 1 To use this function as following procedure requires Sets Auto to Push Lock through OSD menu or communication Sets WB_LOCK Switch ON and holds white This setting can t be saved When power off the camera and turn on the camera this WB setting didapper To save the WB setting OSD menu or communication requires CN2 CN1 Power input Video output UART communication OSD menu c...

Page 13: ...ite balance starts OSD menu control CN1 connector BM6B SRSS TB JST Pin assignment No Signal name Descriptions 1 UP OSD Menu Up 2 ENTER OSD Menu Enter 3 LEFT OSD Menu Left 4 RIGHT OSD Menu Right 5 DOWN OSD Menu Down 6 GND GND CN1 connecting circuit user side example 7 DOWN 8 GND CN2 Pin assignment 1 Up 2 ENTER 3 LEFT 4 RIGHT 5 DOWN 6 GND CN1 Pin assignment A e g i s E l e c t r o n i c G r o u p I ...

Page 14: ...n can manipulate through Remote controller RC S133 connected with CN1 UP ENTER RIGHT DOWN LEFT A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www aegiselect com ...

Page 15: ... 2 20 2 5 Dual Pass Filter φ 15 5 OSD Power Video Comunication 1 5 6 3 6 3 Image 4 87 in Air φ 23 4 M2 Depth 2 5 14 14 8 19 OSD Power Video Comunication 1 5 6 3 6 3 φ 22 4 1 2 16 2 5 5 2 φ 2 3 NTH 2 R1 7 18 16 A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www aegiselect com ...

Page 16: ...al Pass Filter 1 5 Power Video Communication 6 3 6 3 φ 15 φ 16 5 15 22 4 16 8 13 5 5 2 9 2 8 1 2 M12 x P0 5 OSD 4 M3 Depth3 0 2 M3 on other side φ 25 4 M2 Depth3 0 Dual Pass Filter 1 5 Power Video Communication 6 3 6 3 φ 15 φ 16 5 15 22 4 16 8 A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www a...

Page 17: ...M2 Depth 2 5 2 M2 on other side 19 1 14 8 13 6 7 6 10 1 2 5 Dual Pass Filter φ 28 20 OSD Power Video Comunication 1 5 6 3 6 3 φ 23 A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www aegiselect com ...

Page 18: ...33 Series Specifications 18 55 5 6 RC S133 Unit mm A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www aegiselect com ...

Page 19: ... port JIG USB2 4 Cable Camera to JIG USB2 KSAF003 5 Control software KSACtrl 6 2 Connecting configuration Please refer to another chapter 6 3 Communication settings UART RS232C compliant Binary communication Baud rate 115 200bps Data bit 8bits Parity None Stop bit 1bit Flow control None A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888...

Page 20: ... camera communication by selecting Port Setting under Comm C in the menu 3 Select Read All button to read all of the register information from the camera 4 All of the camera settings are configurable through the camera control software A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www aegiselec...

Page 21: ...gs changed settings in to the Flash memory on the camera All changed camera settings save to the Flash memory at once Reset Reboot the camera and read out the camera settings from the camera The camera holds the camera settings as the Default camera settings after read out the camera settings Please use this button to synchronize the camera settings and the camera settings information in the camer...

Page 22: ...ngs file then save the camera settings in to the flash memory Comm C Read All DSP Flash same function as bottom of main windows button PortSetting The communication port settings are changeable Mode M Adjustment The individual camera settings are adjustable One Shot The camera settings save to the file and load from the file by the function A e g i s E l e c t r o n i c G r o u p I n c For more in...

Page 23: ...minance for AE AE convergence speed setting Set the AE convergence speed When set greater number the AE convergence speed increases Frame count for dead band Set the number of the frame that use for the AE control start judgement Dead band AE tracking AE Set the AE convergence finish condition AE convergence is finished when AE error is less than this setting and keeps the same condition more than...

Page 24: ...tter is fixed as the selected shutter time and the brightness level is adjusting by the gain Gain Priority setting The AE becomes the gain prioritized AE when set other than 0 while AE mode It is necessary to select the value that between the minimum and maximum gain The gain is fixed as the selected gain and the brightness level is adjusting by the shutter time A e g i s E l e c t r o n i c G r o...

Page 25: ...he flicker less reset function do not work for this mode 50Hz 60Hz Fixed This mode forces to 50Hz 60Hz flicker less function This flicker less function is of when the outdoor detection and the flicker less reset function are working OFF Does not use the flicker less function Set the gain for Scale ME mode The four sets of shutter and gain for User Preset ME mode are changeable Shutter and gain set...

Page 26: ...ortion compensation Select Enable or Disable for the distortion compensation Vignetting compensation settings The vignetting that caused by the lens or housing is compensating function H Optical center V Optical center Set the optical horizontal and vertical center position Radius Set the compensation radius from the optical center position Ellipticity Set the ellipticity ratio Vegnetting compensa...

Page 27: ...he greater value the distortion is reduced When set the smaller value the distortion is extended There are four types A B C and D of the compensation points are available Distortion compensation OFF Distortion compensation ON A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www aegiselect com ...

Page 28: ...settings are changed by the communication software when this setting is OFF Please set OFF and save if the settings that changed by the UART communication as the camera Default settings Save button Save OSD horizontal and vertical start position for the OSD parameter load is valid Note OSD horizontal and vertical start position do not save by DSP FLASH button when the OSD parameter load is valid I...

Page 29: ...ter Cr Set the color Cb and Cr Character edge Set Enable or Disable for the character humming The Default settings for cursor character and character edge are below OSD Y Cr Cb Blend Notes color Cursor 4 h 8 h 8 h 3 h Gray Character F h 8 h 8 h 3 h White Character edge 0 h 8 h 8 h 3 h Black A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc...

Page 30: ... WD exposure ratio fix Max WD exposure ratio Set the exposure ratio for WDR ATR EX function ATR EX contrast gain ATR EX brightness comp ART EX function is improved the visibility based on the brightness information Defog Defog function is improved the visibility with emphasis the contrast and color saturation for the fogged image When selecting Auto for Defog the response sensitivity is adjusting ...

Page 31: ... luminance compensation from ON to OFF L luminance threshold OFF ON Set the threshold for low luminance compensation from OFF to ON High luminance switching time Set the switching time unit second for high luminance compensation Low luminance switching time Set the switching time unit second for low luminance compensation It is necessary to set L luminance ON OFF L luminance OFF ON H luminance OFF...

Page 32: ...m Average Center Spot and Histogram The average brightness of the full image uses for the average photometry mode The weighted brightness of 63 areas 7x9 areas uses for the center photometry mode The weighted brightness of surround frame of the target frame uses for the spot photometry mode A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc...

Page 33: ...e set from 1 Bright to 5 Dark Please set with the monotonous inclement Full ME Tab Set the shutter and gain for the full ME AE mode Set the shutter speed and gain for the long exposure short exposure 1 and short exposure 2 A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www aegiselect com ...

Page 34: ...ction The mask frame can set up to 16 frames In case of the image has vignetting the optimized brightness of the image can keep it by excluding the vignetting area for AE detection A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www aegiselect com ...

Page 35: ...get Hold mode Hold the white balance gain and stop AWB operation Saved white balance gain is applied when power on the camera with the hold mode MWB mode The white balance control with the specific color temperature User mode 5 sets of the R and B gain are selectable OnePush mode The white balance control automatically by the all pull in then hold the white balance gain and stop the white balance ...

Page 36: ...K User mode2 Cloudy weather 6500K User mode3 Halogen light 3200K User mode4 Incandescent light 2900K Please follow below procedure to adjust the user mode white balance under the specific light condition Select all pull in mode with the white target Read CONT_R and CONT_B after select Read button Set value of CONT_R to modex R G and value of CONT_B to modex B G x 0 to 4 mode number A e g i s E l e...

Page 37: ...is the center adjustment position when set 0 h When set 1 h to 5A h the hue changes with the clockwise rotation When set FF h to A6 h the hue changes with the counter clockwise rotation The unit is 1deg step Saturation adjustment Saturation is the center adjustment position when set 80 h When decreases from 80 h to 0 h the image becomes low saturation image When increases from 80 h to FF h the ima...

Page 38: ... same color pixel and subtracts the same color pixel between the target pixel and around pixel Check the subtract with the threshold then the subtract is greater than the threshold then apply the average add to reduce the noise Pixel correlation Y NR function is good function for reduce the noise on the human skin Horizontal C NR The edge component keeps when the brightness is changed If the brigh...

Page 39: ... display Mask x mosaicing Select On Off for the mosicing mask Mask x Y Cb Cr blend data Y Cb Cr blend rate Set the brightness and color for the mask Examples Y blend rate Cb Cr blend rate Y blend data Display color 1 0 3 h 1 0 3 h F h White 1 0 3 h 1 0 3 h 0 h Black Mask x H start position h end position v start position v end position Set the mask display position Mask Gate When set on this the m...

Page 40: ...ce of threshold for dark side and light side is too small Day to Night Night to Day judgement time Set the judgement time for switching the mode The unit for the judgement time is set unit at counter unit IR optimizer This function set the optimize exposure for the IR light under the dark condition IR photometry mode This function is enabled when the IR optimize is enabled Please check the AE weig...

Page 41: ...h x1 enhancement Analog Tab Camera Type Display the camera type NTSC or PAL Monochromatic output The monochrome image is output when select ON Mute Set the mute Disabled video output of the image Y LPF C LPF Set the LPF for the Y signal and C chroma signal A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect c...

Page 42: ...to the too bright not shading the camera saved compensated values are cleared Info Tab Display the version information of the flash memory data on the camera Field Table Display the list of the settings Initial is first time read out data after the control software started A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegi...

Page 43: ...p Read DSP Read DSP data form the camera and make setting file Write FALSH Write selected setting file into camera s DSP and load to Flash and verify Verify Verify DSP register value to setting file A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www aegiselect com ...

Page 44: ... the camera Please check the OSD section C Controller circuit D Switch button function Below function is assigned for each button ENTER Display OSD menu select setting UP Select up menu selection DOWN Select down menu selection LEFT Select left setting selection RIGHT Select right setting selection OSD operation by the communication software A It is necessary to disable the OSD switch function by ...

Page 45: ...mpensation Default OFF DEFOG Defog Function Default OFF WDR ATR WDR ATR Setting Default WDR and ATR ON Page 2 DAT NIGHT Day Night Setting Default AUTO PRIVACY Privacy Mask Default OFF LANGUAGE OSD Language Default ENGLISH A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www aegiselect com ...

Page 46: ...LUMINANCE AGC Select AGC mode ON OFF Default ON AE LEVEL Set the target brightness level for AE AGC Default X1 00 2 MANUAL SETUP Set up the ME Manual Exposure settings SHUTTER Select shutter speed Default 1 60 AGC Set the gain Default MIN Gain 0 A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www...

Page 47: ...switch automatically 1 and 2 are sensitivity different mode PUSH All pull in white balance mode USER1 USER2 User white balance mode Sets B and G Gain on user setting USER1 B GAIN Default 139 R GAIN Default 208 USER2 B GAIN Default 185 R GAIN Default 202 Set the B gain and R gain for User White balance MANUAL Manual White balance mode Select the color temperature for the manual white balance A e g ...

Page 48: ... LIGHT OFF Back light compensation is OFF BLC Back light compensation is ON HLC HLC High Luminance Compensation is enabled A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www aegiselect com ...

Page 49: ...AST Set the contrast of the image Default 128 SHARPNESS Set the sharpness of the image Default 64 HUE Set the hue of the image Default 90 COLOR GAIN Set the color saturation of the image Default 128 DEFOG LEVEL Set the defog level and sensitivity LOW Low MID Middle HIGH High A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 ae...

Page 50: ...ST Set the contrast highlight level LOW Low MID Middle HIGH High WDR BRIGHTNESS Set the brightness compression level LOW Low MID Middle HIGH High CONTRAST Set the contrast highlight level LOW Low MID Middle HIGH High A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www aegiselect com ...

Page 51: ...ault 110 BURST OFF No burst signal ON With burst signal DNR Set the noise reduction settings MODE OFF Noise reduction is OFF Y C Y C Filter is ON Default Y Y Filter is ON C Filter is OFF C Y Filter is OFF C Filter is ON Y LEVEL Set the Y filter level Default 4 C LEVEL Set the C filter level Default 4 A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic...

Page 52: ...position Default 0 COLOR Se the color for the privacy mask Default 1 TANSP 0 00 050 0 75 1 00 Set the transparent level for the privacy mask Default 0 00 MOSAIC OFF Mosaic is OFF Default ON Mosaic is ON A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www aegiselect com ...

Page 53: ... OSD settings SAVE ALL Save all OSD settings to the flash memory on the camera It is necessary to enable OSD parameter Load function to use saved settings A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www aegiselect com ...

Page 54: ...perature information 05 2017 05 25 Revised Maximum Operational temperature Revised Address TEL FAX number for relocation 06 2017 07 03 Revised Change the name of company 07 2017 07 28 Revised Change Optical size 08 2017 08 28 Revised Added LS model 09 2018 05 01 Revised Change the dimension drawing for L and LS models Note Product specifications would be modified without notification A e g i s E l...

Page 55: ... 09 STC S133 Series Specifications 55 55 A e g i s E l e c t r o n i c G r o u p I n c For more information please contact Aegis Electronic Group Inc 888 687 6877 aegis g2 aegiselect com http www aegiselect com ...

Reviews: