Appendices
A - 124
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Event name
Object Error
Event code
14A9 0000 hex
Description
The object area data in non-volatile memory is corrupted.
Source
EtherCAT Master Function Module
Source
details
Slave
Detection
timing
When
establishing
communications
after turning ON
power to the
slave
Error
attributes
Level
Minor fault
Recovery
Error reset
(after cycling slave
power)
Log category
System
Effects
User program
Continues.
Operation
Power drive circuit is OFF for relevant slave.
Indicators
EtherNet/IP NET RUN
EtherNet/IP NET ERR
EtherNet/IP LINK/ACT
–
–
–
System
-defined
variables
Variable
Data type
Name
None
–
–
Cause and
correction
Assumed cause
Correction
Prevention
Noise
Reset all of the objects. Take noise
countermeasures.
Reset all of the objects. Take
noise countermeasures.
Non-volatile memory failure
If the error persists, replace the
Servo Drive.
None
Attached
information
None
Precautions/
Remarks
“36” is displayed on the Servo Drive front panel and F136 is given as the AlarmCode (4001 hex).
Event name
Object Error
Event code
14AA 0000 hex
Description
The object area data in non-volatile memory is corrupted.
Source
EtherCAT Master Function Module
Source
details
Slave
Detection
timing
When
establishing
communications
after turning ON
power to the
slave
Error
attributes
Level
Minor fault
Recovery
Error reset
(after cycling slave
power)
Log category
System
Effects
User program
Continues.
Operation
Power drive circuit is OFF for relevant slave.
Indicators
EtherNet/IP NET RUN
EtherNet/IP NET ERR
EtherNet/IP LINK/ACT
–
–
–
System
-defined
variables
Variable
Data type
Name
None
–
–
Cause and
correction
Assumed cause
Correction
Prevention
Noise
Reset all of the objects. Take noise
countermeasures.
Reset all of the objects. Take
noise countermeasures.
Non-volatile memory failure
If the error persists, replace the
Servo Drive.
None
Attached
information
None
Precautions/
Remarks
“36” is displayed on the Servo Drive front panel and F236 is given as the AlarmCode (4001 hex).