4.2 GEP parameter setting method
Step 1
Select a GEP number with cursor
keys.
Pressing the F2 key (INIT) initializes all the
GEP communication parameter.
Refer to "4.3 Initializing communication
parameters" in this Chapter for details.
Selecting the GEP number
Step 1
Step 2
Press the F1 key (EDIT) to display
GEP edit screen.
Editing the GEP
Step 2
Step 3
Set the parameters.
Press the F1 key (CREATE) to set a new GEP
parameter, and a pop-up screen appears.
Input a TCP port number to set and press
[OK], and a new GEP parameter will be
created.
Select the items to edit, input the setting
values and press the ENTER key.
NOTE
•It is not necessary to create new parameters
when editing GEP parameters already set.
•Pressing the ESC key halfway cancels the edited
contents.
Creating new GEP
Step 3
Step 4
Press the ESC key to exit the data
editing.