4-32
4-3 Wiring Conforming to EMC Directives
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
4
System Design
Radio Noise Filter and Emission Noise Prevention Clamp Core
Use one of the following filters to prevent switching noise of PWM of the Servo Drive and to
prevent noise emitted from the internal clock circuit.
*1. Generally used for 1.5 kW or higher.
*2. Generally used for 1.5 kW or lower. The maximum number of windings is 3 turns.
*3. Generally used for 50/100 W. The maximum number of windings is 2 turns.
*4. Also used on the Drive output power lines to comply with the EMC directives. Only a clamp is used.
This clamp can also be used to reduce noise current on a FG line.
External Dimensions
Model
Manufacturer
Application
3G3AX-ZCL1
*1
OMRON
For Drive output and power cable
3G3AX-ZCL2
*2
OMRON
For Drive output and power cable
ESD-R-47B
*3
NEC TOKIN
For Drive output and power cable
ZCAT3035-1330
*4
TDK
For Encoder cable and I/O cable
2
−
M5
3
−
M4
95
26
78
80
12.5
72
50
7
39.5
3G3AX-ZCL2
3G3AX-ZCL1
51.5
φ
25.5
17.5
φ
5.1
3.0
6.5
34.0
ESD-R-47B
34
13
30
39
ZCAT3035-1330
83
±
2
35
31.5
80
130
85
180
±
2
160
±
2
7
×
14 Long hole
φ
7