![Omron OMNUC G5 R88D-KN series User Manual Download Page 180](http://html1.mh-extra.com/html/omron/omnuc-g5-r88d-kn-series/omnuc-g5-r88d-kn-series_user-manual_742785180.webp)
4-15
4-2 Wiring
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
4
System Design
R88D-GN30H/-GN50H-ML2
Terminal Block Specifications
R88D-KN06F-ML2/-KN10F-ML2/-KN15F-ML2/-KN20F-ML2
Main Circuit Connector Specifications (CNA)
Motor Connector Specifications (CNB)
Symbol
Name
Function
L1
Main circuit power supply
input
R88D-KNxH-ML2 (3 to 5 kW): 3-phase 200 to 230 VAC (170 to 253
V) 50/60 Hz
L2
L3
L1C
Control circuit power
supply input
R88D-KNxH-ML2: Single-phase 200 to 230 VAC (170 to 253 V) 50/
60 Hz
L2C
B1
External Regeneration
Resistor connection
terminals
Normally B2 and B3 are short-circuited. If there is high regenerative
energy, remove the short-circuit bar between B2 and B3 and
connect an External Regeneration Resistor between B1 and B2.
B2
B3
U
Motor connection
terminals
Red
These are the output terminals to the Servomotor.
Be sure to wire them correctly.
V
White
W
Blue
Green/
Yellow
Frame ground
This is the ground terminal. Ground to 100
or less.
Symbol
Name
Function
L1
Main circuit power supply
input
R88D-KNxF-ML2
(600 W to 2 kW) : 3-phase: 380 to 480 VAC (323 to 528 V) 50/60
Hz
L2
L3
Symbol
Name
Function
U
Motor connection
terminals
Red
These are the output terminals to the Servomotor.
Be sure to wire them correctly.
V
White
W
Blue
Green/
Yellow
Frame ground
This is the ground terminal. Ground to 100
or less.