NYML Recommendations for Custom Cables
The following table lists the recommended cables and connectors for custom NY Monitor Link cables.
Item
Intra cabinet or
light industrial en-
vironment
Inter cabinet
Inter cabinet and
harsh industrial
environment
Maximum length
25 m
100 m
100 m
Manufacturer
Lapp
Lapp
Lapp
Cable type
2170196
2170614
2170466
Category type
Cat 6A
Cat 7
Cat 6A
Cable sheath
Halogen free
Halogen free
Halogen free
Conductor pairs/size/type
4 x 2 x AWG23/1
4 x 2 x AWG23/1
4 x 2 x AWG22/1
Overall shielding
Aluminum foil
Copper braid
Copper braid
Pair shielding
Aluminum foil
Aluminum foil
Aluminum foil
Maximum outer diameter
7.6 mm
7.7 mm
9.0 mm
Maximum bending radius of cable in a fixed
position
31 mm
31 mm
90 mm
Maximum temperature for a cable in a fixed
position
60°C
60°C
80°C
RJ45 connectors
Manufacturer
Stewart Connector
Stewart Connector
Lapp
Partnumber
SS39200-027 or
SS39200-030
SS39200-027 or
SS39200-030
21700600 (T568A)
or 21700601
(T568B)
Connector length
30 mm
30 mm
50 mm
Additional Information
When making cables, connect the shield to the connectors at both ends.
NY Monitor Link Cable Clearance
Ensure to prevent excessive strain on the connector and cable assembly.
The minimum clearance consists of the sum of:
• Connector length
• Maximum bending radius of cable in a fixed position
3 Hardware
3-30
NY-series Industrial Panel PC Hardware User's Manual (W555)
Summary of Contents for NYP - 1 Series
Page 4: ...Introduction 2 NY series Industrial Panel PC Hardware User s Manual W555...
Page 10: ...Index CONTENTS 8 NY series Industrial Panel PC Hardware User s Manual W555...
Page 44: ...1 Overview 1 10 NY series Industrial Panel PC Hardware User s Manual W555...
Page 261: ...I Index I 1 NY series Industrial Panel PC Hardware User s Manual W555 I...
Page 264: ...Index I 4 NY series Industrial Panel PC Hardware User s Manual W555...
Page 265: ......