Additional Information
• The default
Input sensitivity setting
is
Standard voltage sensitivity
and this is correct.
Do not set this parameter to
Low voltage sensitivity
. Doing so can cause a system malfunc-
tion when switching to battery mode.
• The UPS Setting Utility can not be used when the Power Attendant Lite Utility is active.
To use the UPS Setting Utility:
1. Right-click the Power Attendant Lite Utility icon and select Agent Stop.
2. Use the UPS Setting Utility.
3. Right-click the Power Attendant Lite Utility icon and select Agent Start.
5-8-2
Connect UPS Using the I/O Connector
The I/O connector of the Industrial Panel PC:
• receives the power status of the UPS with the UPS Mode Input when the Panel PC has a Windows
operating system. For other operating systems this input is not functional.
• indicates the power status of the Panel PC to the UPS with the Power Status Output.
Additional Information
• A UPS connection using the I/O connector is only possible for a Panel PC with a Windows
operating system. For all other operating systems use the USB connector to connect the
UPS.
Refer to
5-8-1 Connect UPS Using the USB Connector
on page 5-51 for details.
• The Panel PC does not react automatically to the UPS Mode Input.
A custom software program is required
to shut down the Panel PC when needed.
UPS Drivers and the required software is available.
• For Panel PCs with Windows 10 or Windows 7 preinstalled:
• Drivers for the S8BA UPS are pre-installed
• Installation files and manual for the UPS Settings Utility are availabe in the installer directory
D:\OMRON-NY\Installers\ UPS Settings Utility
• For all other Panel PCs following software can be downloaded:
• Drivers for the S8BA UPS from this OMRON website.
• Installation files and manual for the UPS Settings Utility (Windows only) from this OMRON web-
Precautions for Safe Use
• Always use the recommended uninterruptible power supply (UPS) to prevent data loss and
other system file integrity issues caused by unexpected power interruption.
• Use an Omron S8BA UPS with the correct revision number to prevent improper system shut-
down.
• Correctly perform wiring and setting, and ensure that the shutdown by the UPS can be exe-
cuted.
Follow the steps below to connect the S8BA UPS to the I/O connector of the Panel PC and to config-
ure it correctly.
Refer to
on page 5-38 for I/O Connector details.
1
Ensure the revision number of the UPS is correct.
5 Installation
5-53
NY-series Industrial Panel PC Hardware User's Manual (W555)
5-8 Connect UPS
5
5-8-2
Connect UPS Using the I/O Connector
Summary of Contents for NYP - 1 Series
Page 4: ...Introduction 2 NY series Industrial Panel PC Hardware User s Manual W555...
Page 10: ...Index CONTENTS 8 NY series Industrial Panel PC Hardware User s Manual W555...
Page 44: ...1 Overview 1 10 NY series Industrial Panel PC Hardware User s Manual W555...
Page 261: ...I Index I 1 NY series Industrial Panel PC Hardware User s Manual W555 I...
Page 264: ...Index I 4 NY series Industrial Panel PC Hardware User s Manual W555...
Page 265: ......