4 Monitoring the Temperature in Control Panel with the Main Unit and the Software Tool
K6PM-TH Thermal Condition Monitoring Device User’s Manual (H231)
4
-3
Ala
rm
Th
resho
ld Set
ting
4
4-3
Alarm Threshold Setting
The alarm threshold setting of the Main Unit depends on the following procedure.
1
When setting the alarm threshold to automatic setting, be sure to perform monitoring for a few
days in advance. This will enable automatic storage of the maximum temperature for each seg-
ment and the maximum temperature of the sensor internal temperature inside the Main Unit (by
the maximum value holding function in the built-in flash memory).
2
Select the sensor number on the
Monitoring K6PM
Screen of the software tool, and then click
the
Details
Button. The
Monitoring sensor
Screen will appear.
3
Click the
Threshold set
Tab.
Set alarm threshold to automatic setting, or perform correction of the automatic setting parame-
ter, or perform manual setting.
During correction of the
automatic setting paramete
or during manual settings,
enter the threshold value fo
each segment and the sens
internal temperature.
The threshold setting
parameter is written to
the Main Unit either
automatically or manually.
The standard temperature used
in the automatic calculation of
threshold is displayed here.
Click here for automatic
calculation of threshold.
Summary of Contents for K6PM-TH
Page 56: ...2 Installation and Wiring 2 20 K6PM TH Thermal Condition Monitoring Device User s Manual H231...
Page 76: ...3 Initial Setting 3 20 K6PM TH Thermal Condition Monitoring Device User s Manual H231...
Page 156: ...7 Troubleshooting 7 8 K6PM TH Thermal Condition Monitoring Device User s Manual H231...
Page 195: ...I 1 I K6PM TH Thermal Condition Monitoring Device User s Manual H231 Index...
Page 197: ......