UP/DOWN Command Frequency Memory (n62)
• This function changes the reference frequency by turning the UP and
DOWN commands on and off.
• In order to use this function, set n39 for multi-function inputs 4 to 34. Then
the multi-function input 3 (S4) and multi-function input 4 (S5) terminals
are set as described below.
Multi-function input 3 (S4): UP command (The value in n38 for multi-
function input 3 is ignored.)
Multi-function input 4 (S5): DOWN command
• The output frequency held by the UP/DOWN function will be stored in the
memory if n62 for UP/DOWN command frequency memory is set to 1.
• By setting n62 to 1, the frequency reference kept on hold for 5 s or more
will be retained even after a power interruption, and operation will be
restarted at this frequency the next time the RUN command is input.
• The stored output frequency will be cleared from the memory if n62 is set
to 0. The retained frequency is initialized with n01 for parameter
initialization set to 8 or 9.
Note
While this function is used, frequency references can be used with the UP/
DOWN command or inching frequency command. All multi-step speed
references are disabled.
n62
Frequency Hold Function Selector
Changes during
operation
No
Setting
range
0, 1
Unit of
setting
1
Default setting
0
Summary of Contents for J7 series
Page 12: ...XII...
Page 15: ...1 CHAPTER 1 Overview 1 1 Function 2 1 2 Nomenclature 3...
Page 54: ...40 Outline of Operation Chapter 3 2...
Page 102: ...88 Other Functions Chapter 6 7...
Page 158: ...144 Option Specifications Chapter 9 3...
Page 159: ...145 CHAPTER 10 List of Parameters List of Parameters 146...
Page 172: ...158 List of Parameters Chapter 10...
Page 173: ...159 CHAPTER 11 Using the Inverter for a Motor Using the Inverter for a Motor 160...