background image

Automatic Wrist 

Blood Pressure Monitor 

with 

Instruction Manual

ENGLISH 

Model

HEM-629CAN

HEM-629CAN-IM-8139.qxp  5/28/09  7:14 PM  Page 1

Summary of Contents for IntelliSense HEM-629CAN

Page 1: ...Automatic Wrist Blood Pressure Monitor with Instruction Manual ENGLISH Model HEM 629CAN HEM 629CAN IM 8139 qxp 5 28 09 7 14 PM Page 1 ...

Page 2: ...ery Installation 8 Setting the Beep Symbol 9 Setting the Date and Time 10 Applying the Wrist Cuff 12 Taking a Measurement 13 Using the Memory Function 15 Care and Maintenance Care and Maintenance 17 Error Indicators 18 Troubleshooting Tips 19 FCC Statement 20 Warranty 21 Specifications 22 Notes 23 CONTENTS 2 HEM 629CAN IM 8139 qxp 5 28 09 7 14 PM Page 2 ...

Page 3: ...etects your blood s movement through your artery and converts the movements into a digital reading An oscillometric monitor does not need a stethoscope so the monitor is simple to use Clinical research has proven a direct relationship between blood pressure in the wrist and blood pressure in the arm Changes in wrist blood pressure reflect changes in arm blood pressure because the arteries in the w...

Page 4: ...luded in the box before using the unit Contact your physician for specific information about your blood pressure Follow the instructions of your healthcare provider Operate the unit only as intended Do not use for any other purpose The unit is intended for use in measuring blood pressure and pulse rate in adult patient population Do not use on infants or persons who cannot express their intentions...

Page 5: ...n still and do not talk during the measurement 7 Keep a record of your blood pressure and pulse readings for your physician A single measurement does not provide an accurate indication of your true blood pressure You need to take and record several readings over a period of time Try to measure your blood pressure at the same time each day for consistency 8 Wait 2 3 minutes between measurements The...

Page 6: ...6 KNOW YOUR UNIT Main Unit Components Two AAA Alkaline Batteries Storage Case Display MEM Button START STOP Button SET Button Wrist Cuff Battery Compartment HEM 629CAN IM 8139 qxp 5 28 09 7 14 PM Page 6 ...

Page 7: ...Value Symbol Heart Symbol Pulse Display Beep Symbol Date Time Display Diastolic Blood Pressure Systolic Blood Pressure Cuff Deflation Symbol Memory Value Symbol Low Battery Symbol HEM 629CAN IM 8139 qxp 5 28 09 7 14 PM Page 7 ...

Page 8: ...ry cover is securely in place BATTERY REPLACEMENT Initial Set Up When the Low Battery Symbol appears on the display screen remove all the batteries Replace with two new batteries at the same time When the Low Battery Symbol blinks a brief period of usage remains Long life alkaline batteries are recommended NOTES Measurement values stored in the memory will not be deleted during battery replacement...

Page 9: ...f the last reading NOTE If only two readings are stored in the memory for the 10 minute period the average is based on the two readings If one reading is stored in the memory for the 10 minute period this reading is displayed as the average 1 Press the SET button The Beep Symbol on oFF will appear Press the MEM button to adjust Press SET button to set mode The year flashes on the display HEM 629CA...

Page 10: ...30 it will return to 2005 Press the MEM button to advance by increments of one year Press the SET button to set the current year The month flashes on the display NOTE Press and hold the MEM button to increase the values faster 3 SETTING THE MONTH Press the MEM button to advance by increments of one month Press the SET button to set the current month The day flashes on the display 10 SETTING THE DA...

Page 11: ...ton to advance by increments of one hour Press the SET button to set the current hour The minutes flash on the display 6 SETTING THE MINUTE Press the MEM button to advance by increments of one minute Press the SET button to set the current minute The Beep Symbol on or oFF appears on the display 7 Press the START STOP button to turn the display off SETTING THE DATE AND TIME HEM 629CAN IM 8139 qxp 5...

Page 12: ... the cuff leaving a clearance of approximately 1 2 to 1 inch between the cuff and the bottom of your palm 4 Hold the bottom part of the cuff and wrap it around the wrist so it fits comfortably and securely around your wrist NOTE Make sure the wrist cuff does not cover the protruding part of the wrist bone on the outside of the wrist 5 Fold the remaining part of the wrist cuff back out of the way A...

Page 13: ...Press the START STOP button All display symbols appear on the screen The cuff starts to inflate automatically Hold the monitor at heart level until the measurement is complete During measurement the monitor if set to on will beep in rhythm with your heart beat NOTE To stop the inflation or measurement push the START STOP button The monitor will stop inflating start deflating and will turn off HEM ...

Page 14: ...blood pressure and pulse rate are displayed NOTES The time and date of the measurement are displayed alternately A final 3 beeps will sound when measurement is complete 5 Press the START STOP button to turn the monitor off NOTE The monitor will automatically turn off after two minutes Alternating Display HEM 629CAN IM 8139 qxp 5 28 09 7 14 PM Page 14 ...

Page 15: ...he three most recent measurements that were taken within 10 minutes of the most recent reading NOTE If only two readings are stored in the memory for the 10 minute period the average is based on the two readings If one reading is stored in the memory for the 10 minute period this reading is displayed as the average If the date and time is not set the measurement values and the average value will n...

Page 16: ...button to display the values faster Press the SET button to display the measurement values beginning with the oldest values to the most recent values 2 Press the START STOP button to turn the power off TO DELETE ALL VALUES STORED IN THE MEMORY You cannot partially delete records stored in the memory All records will be deleted 1 Press and hold the MEM button and START STOP button simultaneously fo...

Page 17: ... monitor in a safe and dry location Do not fold the cuff tightly Do not subject the monitor to extreme hot or cold temperatures humidity and direct sunlight Avoid subjecting the monitor to strong shocks such as dropping the unit on the floor Remove the batteries if the unit will not be used for three months or longer Always replace all the batteries with new ones at the same time Use the unit cons...

Page 18: ... monitor from your wrist Read Applying the Wrist Cuff on Page 12 Wait 2 3 minutes Take another measurement Batteries are worn Replace the two AAA batteries Refer to page 8 for battery installation Cuff over inflated Remove the monitor from your wrist Read Applying the Wrist Cuff on Page 12 Wait 2 3 minutes Take another measurement Abnormal unit function Repair Service Required Refer to Warranty In...

Page 19: ...proper placement of the battery polarities Measurements values appear too high or too low Blood pressure varies constantly Many factors including stress time of day how you wrap the cuff may affect your blood pressure Review the sections Before Taking a Measurement and Taking a Measurement HEM 629CAN IM 8139 qxp 5 28 09 7 14 PM Page 19 ...

Page 20: ...llowing measures Reorient or relocate the receiving antenna Increase the separation between the product and the receiver Connect the product into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help POTENTIAL FOR RADIO TELEVISION INTERFERENCE for Canada only This digital apparatus does not exceed the Class B...

Page 21: ... 800 634 4350 for the address of the repair location and the return shipping and handling fee Enclose the Proof of Purchase Include a letter with your name address phone number and description of the specific problem Pack the product carefully to prevent damage in transit Because of possible loss in transit we recommend insuring the product with return receipt requested ALL IMPLIED WARRANTIES INCL...

Page 22: ...teries at the room temperature of 73 F 23 C and by using three times a day and inflating to 170 mmHg OperatingTemperature 50 F to 104 F 10 C to 40 C and Humidity 30 to 85 RH Storage Temperature 4 F to 140 F 20 C to 60 C and Humidity 10 to 95 RH Weight of Main Unit Approximately 120 g not including batteries External Dimensions 2 7 8 w 2 1 4 h 1 3 4 d 72 mm 56 mm 44 mm not including the wrist cuff ...

Page 23: ...23 NOTES HEM 629CAN IM 8139 qxp 5 28 09 7 14 PM Page 23 ...

Page 24: ...Made in China OMRON HEALTHCARE INC 1200 Lakeside Drive Bannockburn Illinois 60015 www omronhealthcare com Copyright 2009 Omron Healthcare Inc HEM 629CAN IM 8139 qxp 5 28 09 7 14 PM Page 24 ...

Reviews: