background image

Women’s Advanced 

Automatic Blood Pressure Monitor

with Two Cuffs

Model

Elite 7300W

INSTRUCTION MANUAL

ESP

AÑOL

ENGLISH 

HEM-7300 e-s r2.qxd  11/2/07  4:50 PM  Page 1

Summary of Contents for Intelli Sense ELITE 7300W

Page 1: ...Women s Advanced Automatic Blood Pressure Monitor with Two Cuffs Model Elite 7300W INSTRUCTION MANUAL ESPAÑOL ENGLISH ...

Page 2: ...sion Indicator 12 Average Value Symbol 12 Battery Installation 14 Setting the Date and Time 16 Setting the Medication Reminder Alarm 20 Applying the Arm Cuff 24 Taking a Measurement 28 Using the Guest Mode 30 Using the Memory Function 31 Averaging Function 31 To Display the Measurement Values 31 To Delete All Values Stored in the Memory 33 Care and Maintenance Care and Maintenance 34 Error Indicat...

Page 3: ... a digital reading An oscillometric monitor does not need a stethoscope so the monitor is simple to use The Elite 7300W comes with the following components Monitor Standard Arm Cuff Large Arm Cuff 4 AAA Batteries Stylish Zipper Case Instruction Manual printed in English and Spanish Quick Guide Warranty Card Cuff Guide The Elite 7300W IntelliSense Women s Advanced Automatic Blood Pressure Monitor i...

Page 4: ... the equipment or other property OPERATING THE DEVICE Contact your physician for specific information about your blood pressure Self diagnosis and treatment using measured results may be dangerous Follow the instructions of your physician or licensed healthcare provider If battery fluid should get in your eyes immediately rinse with plenty of clean water Contact a physician immediately People with...

Page 5: ...t use the device for any other purpose Dispose of the device components and optional accessories according to applicable local regulations Unlawful disposal may cause environmental pollution Do not use a cellular phone near the device It may result in an operational failure Use only Omron authorized parts and accessories Parts and accessories not approved for use with the device may damage the uni...

Page 6: ...e floor Do not submerge the device or any of the components in water Store the device and the components in a clean safe location Changes or modification not approved by Omron Healthcare will void the user warranty Do not disassemble or attempt to repair the unit or components SAFETY INFORMATION 6 ...

Page 7: ...our arm on a table so that the cuff is at the same level as your heart 6 Remain still and do not talk during the measurement 7 Keep a record of your blood pressure and pulse readings for your physician A single measurement may not provide an accurate indication of your true blood pressure You need to take and record several readings over a period of time Try to measure your blood pressure at about...

Page 8: ...8 KNOW YOUR UNIT Main Unit Operating Instructions Battery Compartment Memory Button Display Date Time Setting Button Air Jack Start Stop Button ...

Page 9: ...ize This sheet simply explains how to choose the correct size cuff with Cuff Guide However please read the instruction manual thoroughly before using the unit 1 Make a loop with your Cuff Guide 2 Fit the looped Cuff Guide on your upper arm 3 Cuff Guide shows your correct cuff Use the cuff with same colored sticker QUICK GUIDE 5318770 0A Use the Cuff Guide to get your upper arm size then choose the...

Page 10: ...ttery Indicator Deflation Symbol Heartbeat Symbol Hypertension Indicator Irregular Heartbeat Symbol Average Value Symbol Memory Symbol Pulse Display Medication Symbol Date Time Display Guest Symbol Systolic Blood Pressure Diastolic Blood Pressure ...

Page 11: ...e monitor is measuring the systolic blood pressure and the diastolic blood pressure If the Irregular Heartbeat Symbol displays with your measurement results we recommend you consult your physician Follow the directions of your doctor MOVEMENT ERROR SYMBOL The Movement Error Symbol is displayed if you move your body during the measurement Please remove the arm cuff and wait 2 3 minutes Take another...

Page 12: ...if the reading is above 135 for the Systolic Blood Pressure value and or 85 for the Diastolic Blood Pressure value USING THE MEMORY FUNCTION The Heartbeat Symbol flashes when the blood pressure reading stored in the memory is above 135 for the Systolic Blood Pressure value and or 85 for the Diastolic Blood Pressure value AVERAGE VALUE SYMBOL The Average Value Symbol is displayed when you press the...

Page 13: ...certain patients including diabetic patients pregnant women and patients with renal failure1 The monitor is not intended to be a diagnostic device WARNING Contact your physician for specific information about your blood pressure Self diagnosis and treatment using measured results may be dangerous Follow the instructions of your physician or licensed healthcare provider Omron Healthcare recommends ...

Page 14: ...d slide the cover off in the direction of the arrow 2 Install 4 AAA size batteries so the positive and negative polarities match the polarities of the battery compartment as indicated 3 Replace the battery cover BATTERY INSTALLATION 14 Battery Cover ...

Page 15: ...the batteries are removed while the unit is still on the date and time will be reset to that of the previous use However the measurement results are not deleted When the batteries are replaced you may need to reset the date and time If the year is flashing on the display screen refer to Setting the Date and Time The supplied batteries may have a shorter life CAUTION Dispose of the device component...

Page 16: ...th the dates and times The monitor can also calculate an average reading based on the three most recent measurements taken within 10 minutes NOTES If only two readings are stored in the memory for the 10 minute period the average is based on the two readings If one reading is stored in the memory for the 10 minute period this reading is displayed as the average 1 TO START THE SETTING Press and hol...

Page 17: ... by increments of one year Press the Date Time Setting button to set the current year The month flashes on the display NOTE Press and hold the Memory button to advance the date and time values faster 3 SETTING THE MONTH Press the Memory button to advance by increments of one month Press the Date Time Setting button to set the current month The day flashes on the display 17 ...

Page 18: ...5 SETTING THE HOUR The time is set using AM or PM Press the Memory button to advance by increments of one hour Press the Date Time Setting button to set the current hour The minute flashes on the display 6 SETTING THE MINUTE Press the Memory button to advance by increments of one minute Press the Date Time Setting button to turn the monitor off SETTING THE DATE AND TIME ...

Page 19: ...appear on the display Press the Date Time Setting button repeatedly until the year flashes on the display 2 Refer to Setting the Date and Time The Medication Symbol No 1 and the current setting on or oFF will appear on the display after the minute has been set 3 Press the START STOP button to turn the monitor off NOTE If you need to change the Date and Time always adjust the Date and Time setting ...

Page 20: ...time of purchase NOTES Press the START STOP button to stop the Medication Reminder Alarm The Medication Reminder Alarm will automatically stop sounding after one minute The Medication Reminder Alarm will not sound when the monitor is taking a measurement 1 TO START THE SETTING Press and hold the Date Time Setting button The Medication Symbol No 1 and the oFF setting appear on the display S SE ET T...

Page 21: ...ory button to alternate between on or oFF 3 SETTING THE HOUR The time is set using AM or PM Press the Memory button to advance by increments of one hour Press the Date Time Setting button to set the hour The minute flashes on the display S SE ET TT TI IN NG G T TH HE E M ME ED DI IC CA AT TI IO ON N R RE EM MI IN ND DE ER R A AL LA AR RM M 21 ...

Page 22: ...n Symbol No 2 and the oFF setting appears on the display 5 SETTING THE MEDICATION REMINDER ALARM 2 Repeat steps from 2 to 4 to set the Medication Reminder Alarm 2 The year flashes on the display after the Medication Reminder Alarm 2 has been set S SE ET TT TI IN NG G T TH HE E M ME ED DI IC CA AT TI IO ON N R RE EM MI IN ND DE ER R A AL LA AR RM M 22 ...

Page 23: ... are correct press the START STOP button to turn the monitor off To change the date and time refer to Resetting the Date and Time on page 19 S SE ET TT TI IN NG G T TH HE E M ME ED DI IC CA AT TI IO ON N R RE EM MI IN ND DE ER R A AL LA AR RM M 23 ...

Page 24: ...and pulse rate in the adult population Do not use this device on infants or persons who cannot express their intentions USE CUFF GUIDE TO CHOOSE THE RIGHT CUFF There are two cuffs included in this unit standard size and large size Use the Cuff Guide to determine which size cuff is right for you based on the circumference of your arm 1 Make a loop with your Cuff Guide APPLYING THE ARM CUFF 24 ...

Page 25: ...Cuff Guide shows your correct cuff Use the cuff with same colored sticker APPLYING THE CUFF ON THE LEFT ARM 1 Make sure the air plug is securely inserted in the main unit APPLYING THE ARM CUFF 25 Use the Standard Cuff Orange Purple Use the Large Cuff ...

Page 26: ... is centered on the inside of your arm and aligned with your middle finger The air tube runs down the inside of your arm The bottom of the cuff should be approximately 1 2 above your elbow 4 Wrap the cuff firmly in place around your arm using the closure strip APPLYING THE ARM CUFF 1 2 inch 1 2 cm Air Tube Blue Arrow ...

Page 27: ...is instruction for Step 3 on page 26 Apply the cuff to your right upper arm so the blue arrow and the air tube runs along the inside of your elbow The bottom of the cuff should be approximately 1 2 above your elbow NOTE Be careful not to rest your arm on the air tube This will restrict the flow of air to the cuff ...

Page 28: ...flates the monitor automatically determines your ideal inflation level This monitor detects your blood pressure and pulse rate during inflation The Heartbeat Symbol flashes at every heartbeat Do not move your arm and remain still until the entire measurement process is completed NOTE To stop the inflation or measurement press the START STOP button The monitor will stop inflating start deflating an...

Page 29: ...mplete the arm cuff completely deflates Your blood pressure and pulse rate are displayed 4 Press the START STOP button to turn the monitor off NOTE The monitor will automatically turn off after two minutes TAKING A MEASUREMENT 29 ...

Page 30: ...not stored in the memory 1 Press and hold the START STOP button for 3 seconds The Guest Symbol appears on the display 2 Release the START STOP button The cuff starts to inflate automatically NOTE To stop the inflation press the START STOP button The monitor will stop inflating start deflation and turn off 3 Inflation stops and the measurement is started When the measurement is completed your blood...

Page 31: ...ot stored in the memory AVERAGING FUNCTION The monitor calculates the average reading based on the three most recent sets of measurement values taken within 10 minutes NOTE If two sets of measurement values are stored in the memory for the 10 minutes period the average is based on the two sets of measurement values If one set of measurement values is stored this is displayed as the average TO DISP...

Page 32: ...he most recent to the oldest NOTE The date and time are alternately displayed with the measurement values Press the Memory button to display the next set of values Press and hold the Memory button to display the values faster 3 Press the START STOP button to turn the power off USING THE MEMORY FUNCTION 32 Alternating display ...

Page 33: ...ss the Memory button to turn the monitor on 2 Press the Memory button again While holding it down press the START STOP button together for more than 5 seconds 3 Press the START STOP button to turn the monitor off NOTE The monitor will automatically turn off after two minutes USING THE MEMORY FUNCTION 33 ...

Page 34: ...leaners Do not attempt to clean the cuff CAUTION Do not submerge the device or any of the components in water Do not subject the monitor to extreme hot or cold temperatures humidity or direct sunlight CAUTION Store the device and the components in a clean safe location CAUTION Do not subject the monitor to strong shocks such as dropping the unit on the floor Remove the batteries if the unit will n...

Page 35: ...ification not approved by Omron Healthcare will void the user warranty Do not disassemble or attempt to repair the unit or components CAUTION Use only Omron authorized parts and accessories Parts and accessories not approved for use with the device may damage the unit CARE AND MAINTENANCE 35 ...

Page 36: ...m cuff Read Taking a Measurement Take another measurement Cuff over inflated Take another measurement and remain still until the measurement is complete Monitor could not detect pulse wave Air plug is not connected Batteries are worn Replace the four batteries Refer to Battery Installation ERROR INDICATORS ERROR INDICATORS ANDTROUBLESHOOTINGTIPS ...

Page 37: ...es Check the battery installation for proper placement of the battery polarities Measurement values appear too high or too low Blood pressure varies constantly Many factors including stress time of day and how you wrap the cuff may affect your blood pressure Review the sections Before Taking a Measurement and Taking a Measurement TROUBLESHOOTING TIPS ...

Page 38: ...y one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the product and the receiver Connect the product into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help POTENTIAL FOR RADIO TELEVISION INTERFERENCE for Canada only This digital apparatus does...

Page 39: ... 634 4350 or visit our website at www omronhealthcare com Enclose the Proof of Purchase Include 5 00 for the return shipping and handling Include a letter with your name address phone number and description of the specific problem Pack the product carefully to prevent damage in transit Because of possible loss in transit we recommend insuring the product with return receipt requested ALL IMPLIED W...

Page 40: ...ses when used 3 times a day with new alkaline batteries when inflated to 170mmHg at 73ºF 23ºC Operating Temperature 50ºF to 104ºF 10ºC to 40ºC 15 to 90 RH Humidity Storage Temperature 4ºF to 140ºF 20ºC to 60ºC 10 to 95 RH Humidity Air Pressure 700 1060 hPa Main Unit Weight Approximately 8 1 2 oz 240 g not including batteries Main Unit Dimensions Approximately 6 3 16 l 2 15 16 w 1 7 32 h 157 mm 74 ...

Page 41: ...in Unit Standard and Large Arm Cuffs Instruction Manual 4 AAA batteries Stylish Zipper Case Quick Guide Warranty Card and Cuff Guide UPC Code 0 73796 73000 0 NOTE These specifications are subject to change without notice SPECIFICATIONS 41 ...

Page 42: ...Manufactured by OMRON HEALTHCARE Made in China Distributed by OMRON HEALTHCARE INC 1200 Lakeside Drive Bannockburn Illinois 60015 www omronhealthcare com Copyright 2007 Omron Healthcare Inc ...