background image

80

60

80

65

35

37.4

27.6

4

GT1

TS04P

TS

PWR

U.ERR

ANALOG UNIT

8

7

9

IN

Accuracy

(

±

0.3% of indication value or 

±

1

°

C,

whichever greater) 

±

1 digit

(

±

0.3% of indication value or 

±

0.8

°

C,

whichever greater) 

±

1 digit

(

±

0.3% of indication value or 

±

0.5

°

C,

whichever greater) 

±

1 digit

Input Type

R,S,K,J,T,B

Pt100,JPt100

-200.0 to 650.0

°

C

Pt100,JPt100

-200.0 to 200.0

°

C

Model

Input points

Input Type

Accuracy

1

Conversion Cycle

Temperature Conversion Data

Insulation Resistance

Withstanding Voltage

TS04T(CST)

R, S, K, J, T, L, B

TS04P(CST)

Pt100, JPt100

4 points

250ms/4 points

Binary Data

20M

Ω

 min. (at 250VDC, across insulated circuits)

500VAC, 1 minute, Detection Current 1 mA

Across I/O unit interface connector and DIN rail,

Across whole terminals and DIN rail

Across Internal Power Supply and each input

Across each input

Across I/O unit interface connector and whole terminals

2

INSTRUCTION MANUAL

Thank you for purchasing this OMRON product.
This manual primarily describes precautions required in installing and
operating the digital controller. Before operating the product, read this
manual thoroughly to acquire sufficient knowledge of the product. Keep
this manual for future reference.

To ensure safe and correct use of this product, also read the following
manuals:
• CompoBus/D (Device net) Multiple I/O Terminal Operation Manual(Cat.

No. W348-E1-1)
The above manual can be obtained from any OMRON sales office or
dealer.

NOTICE

Items shown below are necessary for safe usage.

Please note them carefully.

(1) Never disassemble, repair or modify the product.

(2) Do not submit the product to abnormal shock. Doing so might result in

faulty operation.

(3) Do not use the product in the following places:

- Places subject to icing, condensation, dust or corrosive gas (espe-

cially sulfide gas or ammonia gas)

- Places subject to splashing liquid or oil atmosphere

- Place subject to static electricity or other forms of severe noise

(4) Fit the product to a DIN rail correctly.

(5) Separate the communication cables from power lines or high-tension

lines.

(6) Avoid connecting or disconnecting cables with the power ON. Doing so

might result in trouble or faulty operation.

(7) Keep the communication distance within specifications.

(8) Use the appointed communication cables.

(9) Locking Connector Cables

• Before turning the power ON, make sure that the connector cables

are firmly connected.

• Be sure that I/O interface connector is properly locked into place.

(10) Tightening Screws

Tighten screws to the stipulated torque to prevent faulty operation.

Torque: 0.3 to 0.5 N • m

(11) Never execute panel processing and wiring after installation to avoid

any conductive foreign substance inside the product.

Doing so may cause malfunction.

(12) Cleaning

Never use paint thinner or other solvent to clean the product. Doing so

might melt or discolor the surface. Use standard grade alcohol.

(13) Isolate Internal Power Supply that is connected to the product from I/O

Power Supply that is for load.

(14) Be sure to warm up more than 30 minutes before you use.

SPECIFICATIONS

Ratings

50mA max.

80mA max.

20.4 to 26.4VDC (24VDC -15 to +10%)

10A max., pulse width 1ms max.

3m in total, 1m max. between each unit

-10 to 55

°

C (no condensation)

25 to 85% (no condensation)

-25 to 65

°

C

Mounted in a panel

TS04P/T: 210g typ.,TS04PCST/TCST: 90g typ.

     Current        (I/O unit interface)       

      Consumption

(Internal power supply)         

Internal Circuit Power Voltage

Inrush Current

 Communication distance

I/O unit interface

Ambient Temperature

Ambient Humidity

Storage temperature

Installation

Weight

Characteristics

NOMENCLATURE

DISPLAY

LED name

TS

PWR

U.ERR

Condition

Lit

Lit

Out

Lit

Out

Lit

Out

LED Displaying Color

Green

Red

− 

Green

− 

Red

− 

Normal Conditions

I/O unit interface error

Standby (or Not Powered)

Powered

Not Powered

Unit error (or Not Powered)

Device Operational

Description

DIMENSIONS (unit : mm)

Be sure to  mount on a 35mm DIN rail using the DIN rail attachment hook.
Do not install the product in places to be touched by accident to avoid mal-
function caused by static electricity.
Do not block the ventilation holes on the upper side of product to allow heat
to escape.
Be sure to have enough space around the product when installing.

DIN Rail Attachment

DIP SWITCH SETTING

WIRING

Terminal Arrangement

Connecting Communications Unit and I/O unit

PRECAUTIONS IN USING THE PRODUCT

When the product is used under the circumstances or environment below, ensure

adherence to limitations of the ratings and functions. Also, take countermeasures

for safety precautions such as fail-safe installations.

(1) Use under circumstances or environment which are not described in the

instruction manual.

(2) Use for nuclear power control, railway, aircraft, viecle, incinerator, medical

equipment, entertainment equipment, safety device etc...

(3) Use for applications where death or serious property damage is possible and

extensive safety precautions are required.

6.0mm max.

6.0mm max.

for M3

Industrial Automation Company
Tokyo, JAPAN

OMRON Corporation

1615913-6D

 

 GT1-TS04T/TS04TCST

 

 GT1-TS04P/TS04PCST

TEMPERATURE INPUT UNIT

GT1

TS04P

TS

PWR

U.ERR

ANALOG UNIT

8

7

9

IN

Display

I/O unit interface 

Connector

I/O unit interface 

Connector

DIN rail attachment hook

DIP switch

(Side surface where 

the cassette is 

removed from the 

terminal block)

Casset 

(The cassette model 

names are 

GT1-TS04TCST and 

GT1-TS04PCST)

Terminal Block

(Under the Cover)

SW1

OFF

ON

Set the unit

°

C

°

F

*default setting

SW3

Keep OFF

Model

GT1-TS04T(CST)

GT1-TS04P(CST)

Default Setting

2

0

The product can be connected to a communications unit and other I/O units with a
connecting cable.

Be sure to disconnect the I/O unit connecting cable after drawing out the cassette.

Use I/O unit interface (1) when connect to a communication unit.

Use I/O unit interface (2) when connect to another I/O unit interface (1),
use I/O unit interface (1) when connect to another I/O unit interface (2).

A terminating connector must be at I/O unit interface (2) of the end unit.

* DIP switch setting is read only when the power is turned ON

SW4

OFF

ON

Setting the Setting mode

DIP switch setting enable

Remote setting enable

*default setting

GT1-TS04T

SOURCE

+24V

SOURCE

+0V

 Input0 NC Input1 NC Input2 NC Input3 NC

  +  

+  

+  

  -  

-  

-  

 Input0 NC Input1 NC Input2 NC Input3 NC

A

B

1

2

3

4

5

6

7

8

9

SOURCE

+24V

SOURCE

+0V

 Input0 Input0 Input1 Input1 Input2 Input2 Input3 Input3

 

A B A B A B A B

  B  

B  

B  

 Input0 NC Input1 NC Input2 NC Input3 NC

A

B

1

2

3

4

5

6

7

8

9

GT1-TS04P

Installing and drawing out the cassette

Draw out the cassette towards you while pressing its upper side. (See diagram below.)
Do not draw out the cassette while power in ON.

Install the cassette to the right position with much care for direction. Check if the cas-
sette in installed properly by pulling it slightly.

Input Type and Condition

Input Type K,T in Lower -100

°

C

Input Type L

Input Type R,S in Lower 200

°

C

Input Type B in Lower 400

°

C

Accuracy

±

2

°

C

±

1 digit max.

±

2

°

C

±

1 digit max.

±

3

°

C

±

1 digit max.

Not defined

1  Exceptions in accuracy

The meaning of the each LED is as follows.

GT1-TS04

1

2

3

4

ON

SW

1

SW

4

O

N

0 1

2

3

4

5

6

7

8

9

DIP Switch

Rotaly DIP Switch

Setting of DIP Switch

SW2

OFF

ON

Set the display mode of temperature data

Normal mode

Decimal 2 Columns display mode

*default setting

Setting of Rotary DIP Switch

Position of 

Rotary DIP

Switch

Input

Type

Range

°

C

) 

0

1

2

3

4

5

6

7

8

9

R

S

K

K

J

J

T

L

L

B

0 to 1700

0 to 1700

-200 to 1300

0.0 to 500.0

-100 to 850

0.0 to 400.0

-200.0 to 400.0

-100 to 850

0.0 to 400.0

100 to 1800

Range

°

F

) 

0 to 3000

0 to 3000

-300 to 2300

0.0 to 900.0

-100 to 1500

0.0 to 750.0

-300.0 to 700.0

-100 to 1500

0.0 to 750.0

300 to 3200

Input

Type

Range

°

C

) 

PT100

JPT100

PT100

JPT100

-200.0 to 650.0

-200.0 to 650.0

-200.0 to 200.0

-200.0 to 200.0

Range

°

F

) 

-300.0 to 1200.0

-300.0 to 1200.0

-300.0 to 380.0

-300.0 to 380.0

Setting Impossible except above

GT1-TS04T

GT1-TS04P

* DIP switch setting is read only when the power is turned ON

I/O Unit Connecting cable

(attached to I/O Unit)

Terminating connector

(attached to the

Communications Unit)

I/O Unit Connecting cable

(attached to I/O Unit)

DRT1-COM

MS

NS

TS

No.

COMMUNICATION  UNIT

(

)

(

)

(

)

(

)

GT1

-

TS04P

TS

PWR

U.ERR

ANALOG UNIT

8

7

9

GT1

-

TS04T

TS

PWR

U.ERR

ANALOG UNIT

8

7

9

IN

IN

TS04P

TS04T

Communication unit

GT1

TS04T

TS

PWR

U.ERR

ANALOG UNIT

8

7

9

IN

TS04T

Vertical direction

Do not install the TS04T in

vertical direction as shown on

the left. If installed vertically,

the indication accuracy may

not be satisfied.

2 Measurement condition

     Accuracy does not include accuracy of external
      components (thermocouple, compensating lead wires, etc.)
      not included on this unit.

Reviews: