background image

73

5

Safe

ty contr

o

llers

G9SX-SM

Safety controllers

Standstill monitoring unit

Safe Standstill monitoring unit based on Back-EMF operation for two- and three-
phase systems.

• Ready to use – covering all standard applications without additional setup

• Easy integration in star- and delta wiring

• Clear LED diagnosis of all in- and output signals for easy maintenance

• Applicable up to Safety Category 4 according to EN954-1

Ordering information

Safety standstill monitoring unit

Specifications

Ratings of non-contact door switch controllers

Power input

Inputs

Outputs

Application example

3-phase motor

3-phase motor with star-delta wiring

Safety outputs 

*1

*1

PNP transistor output

Auxiliary outputs 

*1

Power input
Rated supply voltage

Terminal block type

Order code

Instantaneous

3 (Semi-conductors)

2 (Semi-conductors)

24 VDC

Screw terminals

G9SX-SM032-RT

Spring-cage terminals

G9SX-SM032-RC

Item

G9SX-SM032-_

Rated supply voltage

24 VDC

Item

G9SX-SM032-__

Input Voltage

Standstill detection input (Z1-Z2/Z3-Z4) AC 415 Vrms + 10% max.

Maximum power supply frequency 
for AC induction motor

60 Hz max.

Internal impedance

Standstill detection input: approx, 660 k

Ω

EDM input: approx. 2.8 k

Ω

Item

G9SX-SM032-_

Safety Standstill detection output

Sourcing output (PNP)
Load current: 300 mA DC max.

Auxiliary output

Sourcing output (PNP)
Load current: 100 mA DC max.

Feedback loop

KM1/KM2

U

V

W

A2

ES1

ES2

ES3

X1 X2

T31

A1

T32

Z1 Z2

Z2

Z3

Z4

+24V

PLC etc.

G9SX-SM032

lamp

M

KM2

KM1

FUSE

Inverter

Control circuit

Standstill detected

EDM input

KM1

KM2

A2

ES1

ES2

ES3

X1 X2

T31

A1

T32

Z1

Z2

Z2

Z3

Z4

+24V

PLC etc.

G9SX-SM032

lamp

M

KM2

U2 V2 W2

U1 V1 W1

KM1

KM4

KM3

FUSE

Control circuit

Standstill detected

Reviews: