3 - 23
3 Specifications
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
3-1 Ser
v
o Drive Sp
ecification
s
3
3-1-6 C
ontrol Input D
etails
Pin 26: Damping Filter Switching 1 (DFSEL1)
No allocation: Damping Filter Switching 2 (DFSEL2)
This is the default allocation. The logic and allocation of input terminals (CN1 pin 1 to 8, 9, 26 to 33) can
be changed using Input Signal Selection 1 to 10 (Pn400 to Pn409).
Function
When Damping Filter Selection (Pn213) is set to 1 or 2, this signal enables the use of sequence
signals to switch among four damping control filters.
Pin 28: Electronic Gear Switching 1 (GESEL1)
No allocation: Electronic Gear Switching 2 (GESEL2)
This is the default allocation. The logic and allocation of input terminals (CN1 pin 1 to 8, 9, 26 to 33) can
be changed using Input Signal Selection 1 to 10 (Pn400 to Pn409).
Function
These two signals can be used to switch among up to four electronic gear ratio numerators.
Note Electronic Gear Ratio Denominator (Pn010) is common.
Damping Filter Switching 1 (DFSEL1) and Damping Filter
Switching 2 (DFSEL2)
Pn213 set
value
DFSEL1
DFSEL2
Damping Filter 1
Damping Filter 2
Damping Filter 3
Damping Filter 4
1
OFF
–
Enabled
Enabled
ON
–
Enabled
Enabled
2
OFF
OFF
Enabled
ON
OFF
Enabled
OFF
ON
Enabled
ON
ON
Enabled
Electronic Gear Switching 1 (GESEL1) and Electronic Gear
Switching 2 (GESEL2)
GESEL1
GESEL2
Electronic
Gear 1
Electronic
Gear 2
Electronic
Gear 3
Electronic
Gear 4
OFF
OFF
Pn009 enabled
ON
OFF
Pn500 enabled
OFF
ON
Pn501 enabled
ON
ON
Pn502 enabled
Summary of Contents for G5 R88D-KE Series