Installation Direction
For cooling efficiency, install the Power Controller in the correct direction. The
Power Controller generates a lot of heat, and it uses natural heat convection
for cooling. Installing the Power Controller in the wrong direction may cause it
to malfunction or to be damaged.
!WARNING
Install the Power Controller in the direction shown in this manual. The Power
Controller generates a lot of heat and it uses natural heat convection for cool-
ing. Installing the Power Controller in the wrong direction may cause in mal-
functions or accidents.
!WARNING
Leave at least 100 mm of space above and below the Power Controller when
installing it to allow heat to dissipate.
Do not obstruct the area around the Power Controller and especially the area
around the heat sink.
Top
Bottom
Natural
convection
Other devices
Other devices
Other devices
Other devices
100 mm min.
100 mm min.
Airflow
Mounting surface
Specified dis-
tance or longer
Summary of Contents for G3PW
Page 1: ...Cat No Z280 E1 01 User s Manual G3PW Power Controllers...
Page 2: ...G3PW Power Controllers User s Manual Produced November 2008...
Page 3: ...iv...
Page 15: ...xvi...
Page 49: ...34 Wiring for Specific Applications Section 3 4...
Page 61: ...46 Setting Parameters in the Initial Setting Level Section 4 6...
Page 77: ...62 Heater Burnout Detection Section 5 9...
Page 113: ...98 Parameter Settings in the Adjustment Level Appendix B...
Page 117: ...102 Index...
Page 119: ......