background image

General-purpose Relay

 

G2RS

G-5

El

ect

romechanical 

re

lay

s

General-purpose Relay

G2RS

Slim and Space-saving Power Plug-in Relay

• Lockable test button models now available.

• Built-in mechanical operation indicator.

• Provided with nameplate.

• AC type is equipped with a coil-disconnection self-diagnostic 

function (LED type).

• High switching power (1-pole: 10 A).

• Environment-friendly (Cd, Pb free).

• Wide range of Sockets also available.

LR

Model Number Structure

Model Number Legend

1. Relay Function

Blank:

General-purpose

2. Number of Poles

1:

1 pole

2:

2 poles

3. Contact Form

Blank:

SPDT

4. Contact Type

Blank:

Single

5. Terminals

S:

Plug-in

6. Classification

Blank:

General-purpose

N:

LED indicator

D:

Diode

ND:

LED indicator and diode

NI:

LED indicator with test button

NDI:

LED indicator and diode with test button

7. Rated Coil Voltage

Ordering Information

List of Models

G2R      -                 -              -    

1

2

3

4

5

6

7

Classification

Enclosure 

rating

Coil ratings

Contact form

SPDT

DPDT

Plug-in terminal

General-purpose

Unsealed

AC/DC

G2R-1-S

G2R-2-S

LED indicator

G2R-1-SN

G2R-2-SN

LED indicator with test button

G2R-1-SNI

G2R-2-SNI

Diode

DC

G2R-1-SD

G2R-2-SD

LED indicator and diode

G2R-1-SND

G2R-2-SND

LED indicator and diode with test button

G2R-1-SNDI

G2R-2-SNDI

Rated coil voltage

Note:

   When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table.

Example: G2R-1-S 12 VDC (S)

New model

Summary of Contents for G2RS

Page 1: ...rminals S Plug in 6 Classification Blank General purpose N LED indicator D Diode ND LED indicator and diode NI LED indicator with test button NDI LED indicator and diode with test button 7 Rated Coil...

Page 2: ...S Nameplate R99 11 Nameplate for MY Socket Bridge P2RM SR for AC P2RM SB for DC Applicable Socket Description Model DIN rail connecting Socket Mounting DIN rail 50 cm l x 7 3 mm t PFP 50N 1 m l x 7 3...

Page 3: ...contacts of same polarity Vibration resistance Destruction 10 to 55 to 10 Hz 0 75 mm single amplitude 1 5 mm double amplitude Malfunction 10 to 55 to 10 Hz 0 75 mm single amplitude 1 5 mm double ampli...

Page 4: ...tive load cos 0 4 AC resistive load DC resistive load DC inductive load L R 7 ms 5 000 1 000 500 100 50 5 000 1 000 500 100 50 10 000 G2R 1 S Endurance x10 3 operations Switching current A G2R 2 S Swi...

Page 5: ...otors or fluorescent lamps Switching capacity of DC resistive load Properties 1 Pole and 2 Pole Model DIN railing Resistance Base 250 Environmental Protection RT 1 Flammability Class Base Insulator Sp...

Page 6: ...17 5 5 2 5 2 35 5 max 29 max 13 max 5 G2R 1 SND G2R 1 SNDI DC G2R 1 S G2R 1 SD DC G2R 1 SN G2R 1 SNI AC G2R 1 SN G2R 1 SNI DC 1 2 3 4 5 2 4 5 1 3 2 4 5 1 3 1 2 3 4 5 G2R 2 S G2R 2 SN G2R 2 SNI G2R 2 S...

Page 7: ...8 0 max 38 2 max 36 5 max Standard model Option with ejector and label attached P2RF 05 S Terminal Arrangement Top View 11 14 12 A1 A2 32 6 27 6 22 6 24 5 35 4 3 4 28 6 32 6 5 3 92 0 max 18 0 max 38 2...

Page 8: ...30 max 54 max 4 2 dia hole P2RF 05 E 3 2 dia hole Five M3 5 7 85 5 max 16 0 max 48 max Note Pin numbers in parentheses apply to DIN standard 61 max Eight M3 8 3 5 dia hole 16 0 max 48 0 max 61 0 max P...

Page 9: ...6 65 0 5 30 P2RF S 72 0 1 4 7 6 4 5 15 4 3 5 1 2 1 5 7 4 4 6 4 5 15 4 7 4 7 0 3 5 5 20 1 2 8 1 5 7 5 7 5 5 5 20 4 3 5 P2R 05P 1 pole 14 5 max 35 5 max Tolerance 0 1 Mounting Holes P2R 08P 2 pole 36 5...

Page 10: ...3 14 5 max 35 5 max Eight 3 x 1 2 dia holes Terminal Arrangement Bottom View Recommended thickness of the panel is 1 6 to 2 0 mm P2R 057P P2R 087P 4 5 0 1 15 0 1 4 0 1 5 4 0 1 6 0 1 7 0 1 7 5 5 5 20...

Page 11: ...locked position Caution Use an insulated tool when you operate the test button Precautions for P2RF S Connection Do not move the screwdriver up down or from side to side while it is inserted in the h...

Page 12: ...rest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into oun...

Reviews: