4
Using
Tool
240
Using Custom Command
FZ4 User's Manual
Description
After this command practice, input of the measurement trigger is accepted.
Use it in MeasureStop command and a pair.
Example
Perform scene change.
MeasureStop
ChangeScene 2
MeasureStart
Forbid the measurement execution
MeasureStop
MeasureStop <mode>
Parameters
<mode>
mode (integer type)
Return Value
None.
Description
After this command practice, do not accept input of the measurement trigger.
It is necessary to execute MeasureStart command to accept the measurement trigger again.
When an apple is omitted, assume it 0.
Example
Perform scene change.
MeasureStop
ChangeScene 2
MeasureStart
Fetches a part of the character string.
Mid$ (<Character String>,<Starting Position>,<No. of Characters>)
Parameters
<Character String>
The Character String to be extracted (character type).
<Starting Position>
The position to begin extraction (integer type).
<No. of Characters>
The number of characters to be extracted (integer type).
Acesst 1.0 6251194