7
External
Reference
Tables
FZ3 User's Manual
Output result
245
Output result
Data Output
No.
Data name
Set/Get
Data range
0
Judge
Get only
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
5 to
12
Data 0 -
Data 7
Get only
●
ASCII: -99999999.9999 to
999999999.9999
●
Binary: -2147483.648 to 2147483.647
136
Communication method
Set/Get
0: Ethernet
1: RS-232C/RS-422
137
Output format
Set/Get
0: ASCII, 1: Binary
138
Integer
Set/Get
1 to 10
139
Decimal
Set/Get
0: 0 to 4: 4
140
Minus
Set/Get
0: -, 1:8
141
Field separator
Set/Get
0: OFF 1: Comma, 2: Tab, 3: Space,
4: Delimiter
142
Record separator
Set/Get
0: OFF 1: Comma, 2: Tab, 3: Space,
4: Delimiter
143
0 suppress
Set/Get
0: OFF, 1: ON
144 to
147
Output IP address (1 to 4)
(only when "Ethernet" is selected
for the communication method)
Set/Get
Output IP address
149
Output IP address setting
(only when "Ethernet" is selected
for the communication method)
Set/Get
0: Reference to system,
1: Individual specification
Parallel Data Output
No.
Data name
Set/Get
Data range
0
Judge
Get only
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
5 to
12
Data 0 -
Data 7
Get only
BCD: -999 to 999
Binary: -32768 to 32768
128
Data format
Set/Get
0: Binary, 1: BCD
Acesst 1.0 6251194