7
External
Reference
Tables
224
Measurement
FZ3 User's Manual
123
Perturbation
Set/Get
0: OFF
1: ON
124
Difference
Set/Get
0 to 255
125
Inspection
Set/Get
0: Binary
1: Labeling
126
Label No.
Set/Get
0 to 2499
127
Sort condition
Set/Get
0: Area ascending
1: Area descending
2: X ascending
3: X descending
4: Y ascending
5: Y descending
128
Upper limit of label area condition
Set/Get
0 to 999999999.9999
129
Lower limit of label area condition
Set/Get
0 to 999999999.9999
130
Upper limit of quantity judgement
Set/Get
0 to 9999
131
Lower limit of quantity judgement
Set/Get
0 to 9999
132
Upper limit of area judgement
Set/Get
0 to 999999999.9999
133
Lower limit of area judgement
Set/Get
0 to 999999999.9999
134
Upper limit of position X
Set/Get
-99999.9999 to 99999.9999
135
Lower limit of position X
Set/Get
-99999.9999 to 99999.9999
136
Upper limit of position Y
Set/Get
-99999.9999 to 99999.9999
137
Lower limit of position Y
Set/Get
-99999.9999 to 99999.9999
Character Inspection
No.
Data name
Set/Get
Data range
0
Judge
Get only
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
1
Chara. Num
Get only
0 to 32
2
NG Cause
Get only
0x0000 to 0x0007
103
Reflect to overall judgement
Set/Get
0: ON
1: OFF
120 to 123
Dictionary unit number
Set/Get
-1: OFF
0 to 9999
124
Inspection mode
Set/Get
0: OCR
1: OCR + Count
2: OCV
125
Direction
Set/Get
0:
1:
2:
3:
126
Character output
Set/Get
0: OFF
1: ON
127
Character output destination
Set/Get
0: RS-232C/RS-422
1: Ethernet
129
Horizontal succession
Set/Get
0 to 99
130
Vertical succession
Set/Get
0 to 99
Acesst 1.0 6251194