![Omron FQ2 Series User Manual Download Page 97](http://html1.mh-extra.com/html/omron/fq2-series/fq2-series_user-manual_742876097.webp)
4
Settin
g Up In
spections
Inspecting with the Search Inspection Item
FQ2 User’s Manual
95
4-4 Inspecting with the Search Inspection Item
Search Inspection Item
This inspection item is used to perform inspections for shapes or for presence. The image pattern that is to be
measured is registered in advance and measurements are performed to see if the pattern is present or if the
shape is different.
The image pattern that is registered in advance is called the model. The degree to which the image matches
the model is called the correlation.
Setup Procedure for the Search Inspection Item
Step 1
Selecting the Inspection Item
[Inspect]
−
[Inspection]
1
Press an unused inspection item number and press
[Add item.].
2
Press [Search].
Registering inspection items: p. 93
Drag the arrow
at the bottom of the menu upward to display all of the inspection items.
OK
N
G
Search region (region to
search for the model)
Search for sections that are similar to the model.
Model
(desired image pattern)
Sample Settings
Sample Meas
u
rement
+
Note
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......