Adjusting Image Quality
80
FQ2-S/CH User’s Manual
• To ensure stable operation when the FQ2-S1
/FQ2-S2
/FQ2-S4
/FQ2-S4
-M is con-
nected, we recommend that you set the gain to 16.
• If the recommended value is exceeded, the brightness will not be stable and measurement values may be
inconsistent. We recommend that you turn ON the Brightness Connection Mode.
If a slow shutter speed (1/1 to 1/10) and a high gain are set, fixed-pattern noise (fleck and striped noise)
will sometimes occur. Be sure to thoroughly check the images and the measurement results when you
set the shutter speed and gain.
4
Press [ ]
−
[Gain] on the right of the display.
5
Move the bar to the left or right to adjust the
gain.
Moving it to the right will increase the gain and
make the image brighter. Moving it to the left will
reduce the gain and make the image darker.
6
Press [OK].
7
Press [Back].
Parameter
Setting
Description
Shutter speed
Range:
For FQ2-S3*-***, FQ2-S4*-***
1/1 to 1/4,155
For FQ2-S3****-08*, FQ2-S4****-08*
Built-in lighting off: 1/1 to 1/4,155
Built-in lighting on: 1/250 to 1/60,000
(control by lighting emission time)
For FQ2-S1*****, FQ2-S2*****, FQ2-S4*,
For FQ2-S4*****M, FQ2-CH1*****-M
Built-in lighting off: 1/1 to 1/50,000
Built-in lighting on: 1/250 to 1/50,000
Default: 1/250
If the shutter speed is slow, the image
will be bright. If the shutter speed is
fast, the image will be dark.
Gain
For FQ2-S3*****-08*, FQ2-S3*-***, FQ2-S4*****-08*,
FQ2-S4*-***
Range: 0 to 10
Default: 0
For FQ2-S1*****, FQ2-S2***** FQ2-S4****** FQ2-
S4*****-M, FQ2-CH1*****-M
Range: 16 to 64
Default: 16
If the gain is high, the image will be
bright. If the gain is low, the image will
be dark.
Important
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......