2-6 Setting Up Ethernet
FQ2-S1
FQ2-S2
FQ2-S3
FQ2-S4
FQ2-CH
Connecting to Sensors from the Touch Finder
Configurations Consisting of Only Sensors and the Touch Finder
When only Sensors and a Touch Finder are used, IP addresses are automatically assigned.
No settings are required to use Ethernet.
Connections on Existing Networks
If a Sensor or Touch Finder is connected to a network where a PLC or computer is already connected, the
Ethernet settings must be made compatible with the existing network.
Set the IP addresses with one of the following methods.
・
Sensor
(Setup
Mode)
−
[Sensor settings]
−
[Network]
−
[Ethernet]
−
[IP address setting]
1
Press [Fixed].
2
Set the IP address and subnet mask according to the network settings.
・
TouchFinder
(Setup
Mode)
−
[TF settings]
−
[Ethernet]
−
[AUTO]
1
Press [OFF].
2
Set the IP address and subnet mask according to the network settings.
• If you connect the Touch Finder or PC Tool to a Sensor on a different network through a router, set fixed IP
addresses.
• When connecting by EtherNet/IP or PROFINET, set fixed IP addresses for the Sensors.
Note
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......