External Reference Parameters
FQ2-S/CH User’s Manual
513
Appe
ndi
ce
s
9
*1: To acquire the detected text string, use the ITEMDATA2 command.
Bar code (FQ2-S4 series only)
2000
Mea-
sure-
ment
result
Number of read characters
on line 1
Get only 0 to 32
0
---
---
2001
Number of read characters
on line 2
Get only 0 to 32
0
---
---
2002
Number of read characters
on line 3
Get only 0 to 32
0
---
---
2003
Number of read characters
on line 4
Get only 0 to 32
0
---
---
2100
Read character string on
line 1
Get only 32 characters max.
---
---
---
2101
*1
Read character string on
line 2
Get only 32 characters max.
---
---
---
2102
*1
Read character string on
line 3
Get only 32 characters max.
---
---
---
2103
*1
Read character string on
line 4
Get only 32 characters max.
---
---
---
2500+N
(N= 0 to
127*1
Individual read character
Get only 1 character
---
---
---
3000+N
(N= 0 to
127)
Individual similarity
Get only 0 to 100
0
---
---
3500+N
(N= 0 to
127)
Individual stability
Get only 0 to 100
0
---
---
External
refer-
ence
number
Category
Data name
Set / Get
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
0
Mea-
sure-
ment
result
Judgement
Get only
−
2: No judgement
(not measured),
0: Judgement is OK,
1: Judgement is NG,
−
16: Measurement timeout error
−
2
JG
Logged data
5
Index No.
Get only
−
2: No verification pattern,
or reading error
−
1: Verification is NG,
0 to 31: Master data No.
−
2
IN
---
6
Num. of characters
Get only 0 to 1024
0
N
Logged data
7
*1
Characters
Get only 32 characters max.
0
---
---
103
Output
parame-
ter
Reflect
Get only 0: Yes, 1: No
0
---
---
121
Verifica-
tion con-
dition
Verified master data
Set / Get
−
1: OFF
0: Verify all master data
1: Verify master data 0
2: Verify master data 1
31: Verify master data 31
−
1
---
---
122
Partial verif. on/off
Set / Get 0: No
1: Yes
0
---
---
Exter-
nal ref-
erence
number
Category
Data name
Set / Get
Data range
Default
Expres-
sion text
string
Logged data/
Judgement
parameter
...
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......