External Reference Parameters
480
FQ2-S/CH User’s Manual
Shape Search II (FQ2-S1/S2/S3 series or FQ2-S4 series only)
130
Mea-
sure-
ment
condi-
tions
B lower limit
Set / Get 0 to 255
0
---
---
131
B upper limit
Set / Get 0 to 255
255
---
---
132
Grayscale lower limit
Set / Get 0 to 255
0
---
---
133
Grayscale upper limit
Set / Get 0 to 255
255
---
---
External
refer-
ence
number
Category
Data name
Set / Get
Data range
Default
Expression
text string
Logged data/
Judgement
parameter
0
Measure-
ment
result
Judgement
Get only
−
2: No judgement
(not measured)
0: Judgement is OK
−
1: Judgement is NG
−
13: Teaching not performed error
−
14: Figure not registered error
−
15: Out of range error
−
2
JG
Logged
5
Correlation
Get only 0 to 100
0
CR[0] to
CR[31]
Logged
6
Position X
Get only
−
99,999.9999 to 99,999.9999
0
Y[0] to
Y[31]
Logged
7
Position Y
Get only
−
99,999.9999 to 99,999.9999
0
---
Logged
8
Angle
Get only -180 to 180
0
---
Logged
9
Reference X
Get only
−
99,999.9999 to 99,999.9999
255
---
---
10
Reference Y
Get only
−
99,999.9999 to 99,999.9999
0
---
---
11
Reference angle
Get only -180 to 180
255
---
---
12
Detection coordinate
X
Get only
−
99,999.9999 to 99,999.9999
0
---
---
13
Detection coordinate
Y
Get only
−
99,999.9999 to 99,999.9999
255
---
---
14
Count
Get only 0 to 32
0
C
---
103
Output
parame-
ter
Reflect
Set / Get 0: Yes
1: No
0
---
---
120
Model
region
Rotation
Set / Get 0: No
1: Yes
0
---
---
121
Rotation angle upper
limit
Set / Get -180 to 180
180
---
---
122
Rotation angle lower
limit
Set / Get -180 to 180
-180
---
---
133
Mea-
sure-
ment
condi-
tions
Candidate level
Set / Get 0 to 100
80
---
---
External
reference
number
Category
Data name
Set / Get
Data range
Default
Expression
text string
Logged data/
Judgement
parameter
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......