Connecting to More Than One Sensor
386
FQ2-S/CH User’s Manual
7-5 Connecting to More Than One Sensor
FQ2-S1
FQ2-S2
FQ2-S3
FQ2-S4
FQ2-CH
Up to eight sensors can be connected to one Touch Finder or a computer used for PC Tool.
This sections describes how to connect more than one Sensor to a Touch Finder or computer.
Setting the Sensors to Connect
Use the following setting to connect more than one Sensor to a Touch Finder.
Automatically Connecting Sensors
The Touch Finder can detect Sensors and automatically connect to them in the order that it detects them.
The Touch Finder can detect up to 32 Sensors and it can connect to up to eight Sensors at the same time.
Set this parameter to [OFF] to connect to only a specific Sensor.
(Setup Mode or Run Mode)
−
[TF settings]
1
Set [Auto sensor detection] to [ON].
If there are more than eight Sensors available for connection, use [Sensor List] to select the Sensors to connect.
Selecting the Sensors to Connect: p. 388
Note