Inspecting with Color Data Inspection Item
FQ2-S/CH User’s Manual
295
4
Setting Up Inspect
ions
Step 2
Teaching
Teaching means to store the region and the average color in the region as reference data for the measurement.
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Color Data]
−
[Settings] Tab Page
The following data is stored as the measurement reference.
1
Press [Teach].
2
Place the object that is to be used as the measurement reference in front of the camera.
3
Move the rectangle to the location to be measured.
4
Press [OK].
5
Press [TEACH] on the lower right of the display.
The basic settings will be registered when teaching has been completed.
6
Press [Back] to end teaching.
Changing the measurement region: p. 227
Item
Parameter
Description
Reference data
Reference color R
The R average to use as a reference is set automatically.
Reference color G
The G average to use as a reference is set automatically.
Reference color B
The B average to use as a reference is set automatically.
Drag a corner to size the rectangle.
Drag the rectangle to move it.