Inspecting with the Shape Search III Inspection Item
FQ2-S/CH User’s Manual
243
4
Setting Up Inspect
ions
Increasing Processing Speed
The following two methods can be used to reduce processing time.
• Reduce the range in which a shape search III is performed for the model.
Changing the Measurement Region: p. 227
• Reduce the Angle range setting.
Adjust the [Angle range] parameter to reduce the range in which a shape search II for the model is performed.
Select the Results to Output: p. 237
• Raise [Candidate level].
Raise [Candidate level], then processing time will be shortened.
Select the Results to Output p. 221
• Set the Model region as small as possible.
Raise [Candidate level], then processing time will be shortened.
Judgment is NG (Insufficient memory)
The measurement region is possible to use large memory.
Set the measurement region as smaller as possible.
• Set the measurement region to be small.
Changing the Measurement Region: p. 227
・
Set the model region to be small.
The model size is possible to use large memory.
Set the model region as smaller as possible.