Reading 2D-codes
FQ2-S/CH User’s Manual
199
4
Setting Up Inspect
ions
Unstable Reading Results
Reading Is Unstable Due to Low Contrast
Adjust the brightness to improve the contrast of the 2D code.
Adjusting the Brightness: p. 77
Measurement Data That Can Be Used for External Outputs and Calculations
Expression
text string
Data name
Description
Data range
JG
Judgment
This is the judgment result.
−
2: No judgment (not measured),
0: Judgment is OK
1: Judgment is NG
−
16: Measurement timeout error
IN
Index
The verification result
(master data No.) is output.
−
2: No verification pattern, or reading
error
−
1: Verification is NG
0 to 31: Master data No.
N
Num. of characters
The number of characters read is output. 0 to 1024
GD0
Overall quality
Overall quality of 2D code based on ISO/
IEC15415. The lowest grade of the indi-
vidual indices is the overall quality.
0 to 4
GD1
Decode
Evaluates whether decode was success-
ful.
0 to 4
GD2
Cell contrast
Evaluates the difference between the
average of the white cell density and the
average of the black cell density.
0 to 4
GD3
Cell modulation
Evaluates the deviation of cell brightness. 0 to 4
GD4
Fixed pattern damage Evaluates the degree of fixed pattern
damage of the code.
0 to 4
GD5
Axial nonuniformity
Evaluates the degree of vertical and hori-
zontal distortion of the code.
0 to 4
GD6
Grid nonuniformity
Evaluates the position deviation of each
cell.
0 to 4
GD7
Unused err. Corr.
Evaluates the proportion of unused error
correction during decode.
0 to 4
GD8
Print scale
Outputs the print scale.
0 to 4
GD9
Print scale X
Outputs the print scale X direction.
0 to 4
GD10
Print scale Y
Outputs the print scale Y direction.
0 to 4
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......