
Reading Barcodes
186
FQ2-S/CH User’s Manual
Detail Settings
When you execute TEACH, the measurement parameters are automatically set according to the read cords.
[Inspect]
−
[Inspection]
−
[Add item.]
−
[Bar code]
−
[Details] Tab Page
Press [Meas. parameter], and set the measurement parameters.
Be sure to always specify the code type. Specify other items as necessary. If master data is automatically
registered, the code type, the composite codes on/off setting, and the read direction are automatically set.
Setup Item
Setting Value
Description
Code type
JAN/EAN/UPC
(Default)
Selects the type of barcode to be read.
Code39
Codebar
ITF
Code93
Code128/GS1-128
GS1 DataBar
Pharmacode
Code color
Black (Default)
Sets the color of the code to be read.
White
Composite codes on/off
No (Default)
Sets whether or not to support composite codes.
This item is enabled only when the following barcode types are
selected:
Code128/GS1-128, GS1 DataBar
Yes
Check digit on/off
No (Default)
Selects whether or not to insert a check digit. This item is enabled
only when the following barcode types are selected: Codebar,
Code39, ITF (Interleaved 2 of 5), JAN, EAN, UPC, or Code93.
When the other codes are selected, this item is set to ON.
Yes
Direction
Horizontal mode (Default) Selects the reading direction. This item is enabled only when Phar-
macode is selected as the barcode type.
Vertical mode
Reverse on/off
No (Default)
Sets whether or not to use the reverse mode. This item is enabled
only when Pharmacode is selected as the barcode type.
Yes
Timeout
1 to 9999 ms
Default value: 9999
Sets the timeout time in read processing. A read error occurs if
measurement does not end after the preset timeout time is
exceeded.
Summary of Contents for FQ2-S/CH Series
Page 1: ...User s Manual Smart Camera FQ2 S CH Series Cat No Z337 E1 06...
Page 12: ...10 FQ2 S CH User s Manual MEMO...
Page 74: ...Setting Up Ethernet 72 FQ2 S CH User s Manual MEMO...
Page 366: ...Editing the Model Region Measurement Region from Run Mode 364 FQ2 S CH User s Manual MEMO...
Page 432: ...Functions Related to the System 430 FQ2 S CH User s Manual MEMO...
Page 587: ...Index FQ2 S CH User s Manual 585 Index 9...
Page 589: ......