16
Chapter
2
Des
c
ript
io
n o
f Fun
ction
s
F3SJ-E/B
User’s Manual
System Configuration and Functions
Description of Functions
External Test Function
This function stops the emission using an external signal. It can be used to verify that a safety system
should properly stop (safety output turns OFF) when F3SJ-E/B is interrupted.
To stop the emission, apply Vs-3 V to Vs to the emitter's test input line.
Easy Type
Basic Type (basic system)
Basic Type (muting system)
Easy Type
Basic Type (basic system)
Basic Type (muting system)
Test input
Safety output
ON
OFF
60 ms max.
140 ms max.
ON
OFF
Test input
Safety output
ON
OFF
ON
OFF
60 ms max.
140 ms max.
Test input
Safety output
ON
OFF
360 ms max.
140 ms max.
ON
OFF