F3SJ-A
User’s Manual
Wiring/Installation
Output Operation
The external indicator output 1 (on the receiver side) is configured as "safety output reverse output
(ON when blocked)", while the external indicator output 2 (on the emitter side) is configured as "lockout
output (ON during lockout)".
When the muting function is used, both the emitter and receiver are configured as muting/override
output (ON during muting and during override).
Timing chart of basic system
Safety output
ON
OFF
ON
OFF
ON
OFF
Unblocked
/Blocked
Unblocked
Blocked
Lockout
External indicator output 1
External indicator output 2
( Receiver )
( Emitter )