![Omron F3SJ-A P Series User Manual Download Page 112](http://html1.mh-extra.com/html/omron/f3sj-a-p-series/f3sj-a-p-series_user-manual_743263112.webp)
94
Chapter
4
Wiring Examp
le
s
F3SJ-A
User’s Manual
Input/Output Circuit and Applications
Connecting to a G9SA-301
㪪㪋
S1
IN1
IN2
OUT
PLC
KM3
M
KM1
KM2
E1
+DC24V
0V
A1
A2
T11
T12
S2
KM1
KM2
T31
K1
3
4
K2
1
a
b
2
5
T32
41
33
23
13
1
2
3
4
5
6
JP
6
a
b
K1
K2
K1
K2
PE
T21
T23 T22
A
B
14
24
34
42
Control
Circuit
KM1
KM2
*1
11
12
21
22
S3
Emitter
Receiver
Shield
0V (Blue)
(Red)
Open
Test input (Green)
Reset input (Y
ellow)
Interlock selection input (White)
Open
+24V (Brown)
Communication
line (+) (Grey)
Communication
line (-) (Pink)
+24V (Brown)
External devace monitoring input (Red)
Auxiliary output 1 (Yellow)
Safety output 1 (Green)
Safety output 2 (White)
0V (Blue)
Shield
Model G9SA-301
Unblocked
Blocked
External test switch
(S1)
Interlock reset switch
(S2)
Emergency stop switch
(S3)
Control output
K1,K2 N.O. contact
KM1,KM2 N.O. contact
K1,K2 N.C. contact
KM1,KM2 N.C. contact
PLC input 1
PLC input 2
PLC output
S1
:External test switch
S2
:Interlock reset switch
S4
:Lockout reset switch
KM1, KM2 :Magnetic contactor
KM3
:Solid state contactor (G3J)
M :3-phase
motor
E1
:24VDC power supply (S82K)
PLC :Programmable
controller
(Used for monitoring -- not related to safety system)
- F3SJ settings
- Auto reset mode
- Does not use external device monitoring function
- G9SA-301 settings
- Manual reset mode
- Using feedback loop
- Using emergency stop switch
*1 If an emergency stop switch is not used, connect safety
output 1 to T12 terminal and safety output 2 to T23 directly.
S3
: Emergency stop switch (forcibly-opening contact)
(A165E, A22E)
Model F39-JC A-L
Model F39-JC A-D