55
F3SG-SR
User’s Manual
Chapter
2
External Device Monitoring (EDM)
System Operation and Functions
E
Timing chart
2-11-2. Factory Default Setting
The EDM function is disabled.
2-11-3. Setting with Intelligent Tap
The user can select the setting from EDM Enabled or Disabled by the DIP Switch. When enabling
EDM, the function operates under the following condition.
• Allowable delay time *: 0.3 s (factory default setting)
* By using SD Manager 3, this parameter can be set by 0.1 s in a range of 0.1 to 4.0 s.
Make sure the Position 2 of the DIP Switch is set at ON (DIP Switch Enabled) to activate the settings by the DIP Switch.
After making the setting, make sure to perform the wiring so that the specified voltage is supplied into the RESET line of
the receiver without passing through the NC contacts of the external relays, and confirm the F3SG-SR enters the
LOCKOUT state.
ON
OFF
ON
OFF
T1
Lockout
T1 max.
T1: Allowable delay time. This parameter can be set by 0.1 s in a range of 0.1 to 4.0 s.
Unblocked
Blocked
Beam state
OSSD
EDM