336
Chapter
7
Pre-Operation Checklists
F3SG-SR
User’s Manual
Checklists
When the External Test function is used:
When PNP is selected, the OSSD indicator turns red when the TEST line is short-circuited to 9 V to Vs.
When NPN is selected, the OSSD indicator turns red when the TEST line is short-circuited to 0 to 3 V.
When the External Device Monitoring function is used:
When the RESET line is open the OSSD indicator remains red regardless of the beam state of the
F3SG-SR.
When the Start Interlock function is used:
When the F3SG-SR is turned ON and the F3SG-SR is unblocked, the OSSD indicator remains red.
The reset input turns the OSSD indicator to green.
When the Restart Interlock function is used:
When the OSSD indicator is green and the F3SG-SR is blocked and then returned to unblocked
state, the OSSD indicator remains red. The reset input turns the OSSD indicator to green.
When the Muting function is used, minimum muting time limit required must be set.
When the Muting function's operation mode is Exit-Only Muting mode, minimum muting end wait time
required must be set.
Under the MUTING state, a signal that indicates the MUTING state must be given from the AUX line.
When the Override function is used, the minimum override time limit required must be set.
Under the OVERRIDE state, a signal that indicates the OVERRIDE state must be given from the AUX
line.
7-1-1-4. Checking that Hazardous Parts Stop While the Machine Operates
The hazardous parts stop immediately when a test rod is inserted into the detection zone at 3
positions: "directly in front of the emitter", "directly in front of the receiver", and "between the emitter
and receiver". (Use the appropriate test rod.)
The hazardous parts remain stopped as long as the test rod is in the detection zone.
The hazardous parts stop when the power of the F3SG-SR is turned OFF.
The actual response time of the whole machine is equal to or less than the calculated value.
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...