F3SG-R
User’s Manual
Chapter
2
Interlock
System Operation and Functions
E
2-9-4. Setting with Configuration Tool
Some settings of functions configurable with the Configuration Tool may increase risks.
Make sure the Responsible Person conduct a thorough risk assessment analysis before
managing and changing the settings. Unintended changes to the settings may cause a
person to go undetected, resulting in serious injury.
The user can make changes to the settings by the Configuration Tool.
Interlock function
* Setting parameters of this function can be saved according to the states where the Muting function is
enabled and disabled, respectively. After changing the Muting function from Enable to Disable or
from Disable to Enable, also check the settings of this function again.
Considerations for enabling and disabling Muting function
under
for more information.
Pre-Reset function
*1. When the Pre-Reset is enabled, it precedes all other interlock functions and the parameters of Start
Interlock and Restart Interlock are ignored.
*2. It is not possible to configure the Pre-Reset function together with the Muting function. To enable
settings of the Pre-Reset function, disable the Muting function.
In addition, setting parameters of the following functions can be saved according to the states
where the Muting function is enabled and disabled, respectively. After changing the Muting function
from Enable to Disable or from Disable to Enable, also check the settings of these functions again.
Affected functions: External Device Monitoring (EDM), Start Interlock, Restart Interlock, Auxiliary
Output, Lamp Output
*3. The minimum number of times is fixed to 1.
Make sure the Position 8 of the DIP Switch is set to Configuration Tool Enabled to activate the settings by the
Configuration Tool.
Refer to
Safety Light Curtain Configuration Tool for Model F3SG (SD Manager 2) User’s Manual
for more
information on setting this function by the Configuration Tool.
Function
Factory Default Setting
Available Parameters
Muting function enabled*
Muting function disabled*
Start Interlock
Disable
Disable
Enable/Disable
Restart Interlock
Disable
Disable
Enable/Disable
Function
Factory Default Setting
Available Parameters
Pre-Reset
Disable
Enable*1*2/Disable
Maximum number of times F3SG-R can be blocked *3 infinite
1 to 9 times in 1-time increments, or infinate
Maximum permissible time from input of PRE-RESET
signal to input of RESET signal
8 s
1 to 60 s in 1-s increments
Summary of Contents for F3SG-RA
Page 16: ...xiv Introduction F3SG R User s Manual...
Page 24: ...xxii Introduction F3SG R User s Manual...
Page 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Page 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Page 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Page 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...