33
F3SG-R
User’s Manual
Chapter
2
Exter
n
al Test
System Operation and Functions
E
<Timing chart>
2-7-2. Factory Default Setting
The factory default setting is 24 V Active.
2-7-3. Setting with DIP Switch
The user can select the setting from 24 V Active or 0 V Active by the DIP Switch.
Refer to
Chapter 3 Setting with DIP Switch
for more information on setting this function by the DIP Switch.
2-7-4. Setting with Configuration Tool
The user cannot make any changes to the External Test settings by the Configuration Tool.
TEST
OFF
OSSD
ON
OFF
ON
Toff: ON to OFF Response time
Toff x 4 or less
Toff x 12 or less