2-22-3. Setting with DIP Switch
The user cannot make any changes to this function by the DIP Switch.
2-22-4. Setting with Configuration Tool
Some settings of functions configurable with the Configuration Tool may increase risks.
Make sure the Responsible Person conduct a thorough risk assessment analysis before
managing and changing the settings. Unintended changes to the settings may cause a
person to go undetected, resulting in serious injury.
The user can make changes to the settings by the Configuration Tool.
If you want to output the light unblocked/blocked states of a designated beam, configure any one of the
output operation modes of auxiliary output or Lamp as designated beam output information.
Make sure the Position 8 of the DIP Switch is set to Configuration Tool Enabled to activate the settings by the
Configuration Tool.
Refer to
Safety Light Curtain Configuration Tool for Model F3SG (SD Manager 2) User’s Manual
for more
information on setting this function by the Configuration Tool.
Function
Factory Default Setting
Available Parameters
Designated beam output
Disable
Enable/Disable
Designated beam zone
Bottom beam
-
Any beam in 1-beam increments
Top beam
-
Designated beam state
Light-ON
Light-ON/Dark-ON
Summary of Contents for F3SG-RA
Page 16: ...xiv Introduction F3SG R User s Manual...
Page 24: ...xxii Introduction F3SG R User s Manual...
Page 44: ...20 Chapter 1 List of Models F3SG R User s Manual Overview and Specifications...
Page 132: ...108 Chapter 2 Setting Recovery F3SG R User s Manual System Operation and Functions...
Page 208: ...184 Chapter 4 Wiring F3SG R User s Manual Wiring Installation...
Page 244: ...220 Chapter 6 Maintenance Checklists F3SG R User s Manual Checklists...