1-6-2. Calculation of Response Time of Cascaded Segments
The F3SG-4RA-25-02TS can be used in cascade connection among F3SG-4RA-25-02TS's.
In case of a cascade connection, a response time is determined by the total number of beams.
If the total number of beams of all F3SG-R in a cascade connection is 140 or less, its response time is
12 ms (Code A)/13 ms (Code B).
The diagram below summarizes the relation described above.