7-1-2. Warning
7-1-2-1. Description
If an error is detected that prevents the F3SG-R to continue normal operation, the STB indicator blinks
to notify warning information according to the error. The F3SG-R continues normal operation. The
F3SG-R automatically recovers from the warning status when the cause of the error is solved.
7-1-2-2. Troubleshooting
Identify an error according to the combination of the indicators when the error occurs. See the following
troubleshooting tables to take measures.
Description
Warning code
Cause and measures
Malfunction due to ambient
light or vibration
11
Malfunction may have occurred due to ambient light or instantaneous beam
misalignment from vibration.
Check the installation condition.
Take necessary measures against mutual interference according to "
4-1-4. Mutual Interference Prevention
Low incident light level
12
The incident light level may be low due to dirty optical surface or
misaligned beams caused by vibration.
Clean the optical surface and check the alignment of the beams.
Take necessary measures for this according to
.
OFF
Blink
[Warning Description]
Malfunction due to ambient light or vibration
STB
Combination of Indicators and Error
Description
<Indicator status at warning: Receiver>
None
<Indicator status at warning: Emitter>
LOCKOUT
Summary of Contents for F3SG-R Series
Page 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Page 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Page 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Page 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...