83
F3SG-4RA-25-02TS
User’s Manual
Ch
apt
e
r
5
Wir
ing Examples
Input/Output Circuit and Applications
E
5-2-2. EDM not used and External Test in 0V Active used
The following is the example of External Device Monitoring not used and External Test in 0 V Active
(used).
[Settings]
[Wiring Example]
The wiring example does not indicate functional earth. To use functional earth, wire an earth cable according to the
example in
5-2-1. EDM used and External Test in 24V Active not used
. Also refer to
4-5-4. Functional Earth Connection
for more information.
Function
Emitter
External Test: 0 V Active (End Cap: White)
S1: Test Switch (Connect the line to 24 V if this switch is not required)
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
M: Motor
Unblocked
Blocked
Test Switch (S1)
Beam state
OSSD
KM1
KM2
M
KM1 KM2
S1
+24 VDC (Brown)
Not used (Yellow) *1
TEST (Black)
Not used (White) *1
Not used (Red) *1
Not used (Pink)
Not used (Gray)
0 VDC (Blue)
OSSD 1 (Black)
OSSD 2 (White)
+24 VDC (Brown)
0 VDC (Blue)
AUX (Yellow)
PC COM (-) (Pink)
PC COM (+) (Gray)
EDM (Red)
F39-JD
□□
A-L *2
F39-JD
□□
A-D *2
Power Supply
+24 VDC
0 VDC
Receiver
Emitter
*1. The F39-JD
□
RA-L Single-Ended Cable for Emitter (Oil-Resistant
Cable) does not have the red, white and yellow wires.
*2. For the F39-JD
□
A-
□
Single-Ended Cable, connect the shield line
to 0 V.
Summary of Contents for F3SG-R Series
Page 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Page 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Page 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Page 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...