2-8-2. Factory Default Setting
The start interlock and restart interlock are disabled, so the sensor operates as the auto reset mode.
2-8-3. Setting with Intelligent Tap
Auto reset or manual reset can be configured using Positions 4 and 5 of the DIP Switch on the
Intelligent Tap.
When the Manual Reset mode is configured, start Interlock and Restart Interlock are enabled.
Refer to
3-4. LED Indicators on Intelligent Tap
for more information.
• Minimum pressing time of reset switch*: 100 ms (factory default setting)
* By using SD Manager 3, the time can be set by 100 ms in a range of 100 to 500 ms.
Make sure the Position 2 of the DIP Switch is set at ON (DIP Switch Enabled) to activate the settings by the DIP Switch.
Refer to
Chapter 3 Setting with Intelligent Tap
for more information on setting this function by the Intelligent Tap.
2-8-4. Setting with SD Manager 3
The user can make changes to the settings of this function by the SD Manager 3.
* For this function, setting parameters are kept individually in each case that the muting function is set enabled or disabled. When
changing of the muting state from enabled to disabled or vice versa using SD Manager 3, confirm the setting of this function
again.
For details, refer to
Considerations for enabling and disabling Muting function with SD Manager 3
of
.
It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
Refer to
4-3-2-1. Interlock/External Device Monitoring (EDM)/PSDI
for more information on setting this function by the SD
Manager 3.
Function
Initial value
Configurable value or
numerical range
When muting enabled *
When muting disabled *
Start interlock
Disabled
Disabled
Enabled/disabled
Restart interlock
Disabled
Disabled
Enabled/disabled
Minimum pressing time of
reset switch
100 ms
100 ms
100-500 ms (by 100 ms)
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...