50
Chapter
2
O
pera
ting St
ate
s
F3SG-SR/PG
User’s Manual
System Operation and Functions
Refer to
for more information.
TEACH-IN Mode
The two safety outputs are in the OFF state and the green CFG indicator on the receiver is blinking.
Refer to
for more information of the error indication.
SETTING State
The two safety outputs are in the OFF state. In case of F3SG-SR and F3SG-PGA-A/-L, the yellow
TEST, green LONG and green CODE indicators on the emitter and the green CFG and green PNP and
green CODE indicators on the receiver are blinking. In case of F3SG-PGA-C, the CFG, PNP, and
CODE indicators of the emitter/receiver are blinking green. Then, the IN and OUT indicators of the
Intelligent Tap blink in yellow and green, respectively. The SETTING state does not allow the protected
machine to operate. The user can change settings of the functions, monitor the operating states or
view maintenance information (Intelligent Tap, SD Manager 3 or SD Manager 3 Mobile APP) under this
state.
Refer to
Safety Light Curtain Configuration Tool for Model F3SG (SD Manager 2) User’s Manual
for more
information.
2-2-2. Operating States of Intelligent Tap
Backup
The configuration of F3SG-SR/PG is saved in the Intelligent Tap. The machine guarded cannot be
operated. For the system operation and user operation method during backup, refer to
.
Restoration
The configuration in the Intelligent Tap is written into F3SG-SR/PG. The machine guarded cannot be
operated. For the system operation and user operation method during restoration, refer to
IO-Link Communications
While the IO-Link master and Intelligent Tap are in communication, the IO-Link indicator of the
Intelligent Tap blinks in green.
When F3SG-
PGA-C is under
lockout state
Emitter/
Receiver
or
Lockout
Red
Turns ON when it is
under the lockout state
Flashes when it is
under the lockout state
or
Maintenance
Red
Turns ON when the
recoverable lockout
occurred.
Flashes ON when the
replacement-
recommended lockout
occurred.
Intelligent
tap
IN
Sensor
status
Yellow
-
Flashing when F3SG-
PGA-C is under lockout
state
Condition
Device
Indicator
Name
Color
Illuminated
Blinking
E
ERR
M
MAI
N
T
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...