5-1-4. Mutual Interference Prevention
Do not use the F3SG-SR/PG with mirrors in a retro-reflective configuration. Doing so may
hinder detection. It is possible to use mirrors to alter the detection zone to a 90-degree
angle.
When using more than one set of F3SG-SR/PG's in adjacent areas, the emitter of one
F3SG-SR/PG may interfere with the receiver of the other, causing the safety functions to
stop working properly. Install, configure and maintain them so that mutual interference does
not occur.
When two or more F3SG-SR/PG systems are mounted in close proximity to each other, precautions
should be taken to avoid one system interfering with another, such as by beam alignment, back-to-back
configuration, physical barrier, Scan Code Selection, Operating Range Selection or adjusting the
distances from adjacent safety light curtains.
Example
In the Wired Synchronization, mutual interference is prevented in up to 3 sets, using interference light
avoidance algorithm.
In the Optical Synchronization, the scan code feature allows for placement of up to 2 sets of the F3SG-
SR/PG in close proximity and in line with each other. The distinctive coding of the beams provide for
unique operation of a system while in view of another system with a different scan code. Two unique
codes are available.
The emitter and receiver units must be set to the same scan code for the receiver to enter the
MACHINE RUN state. The scan code is selectable by the End Caps on the emitter and receiver units.
Refer to
2-3-1-1. Optical Synchronization
for more information on the scan code feature.
Emitter
Recei
v
er
Machine 1
Emitter
Recei
v
er
Machine 2
PREFERRED I
N
STALLATIO
N
1
Code A
Code A
Emitter
Recei
v
er
Machine 2
Machine 1
Emitter
Recei
v
er
PREFERRED I
N
STALLATIO
N
2
Code A
Code A
Emitter
Recei
v
er
Machine 2
Machine 1
Emitter
Recei
v
er
N
OT RECOMME
N
DED I
N
STALLATIO
N
Code A
Code A
Back-to-
b
ack config
u
ration
Physical
b
arrier
b
et
w
een systems
PREFERRED I
N
STALLATIO
N
3
Emitter
Recei
v
er
Emitter
Recei
v
er
Code A
Code A
Code A
Code A
L
D
5°
5°
er
Distance between emitter and
receiver (operating range L)
Allowable installation distance
D
For 0.2 to 3m
0.26m
For 3m or more
L x tan5 ° = L x 0.088 (m)
Machine 1
Emitter
Emitter
Recei
v
er
Machine 2
Recei
v
er
Code A
Code B
Scan code setting
w
hen t
w
o or more systems are mo
u
nted
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...