299
F3SG-SR/PG
User’s Manual
Ch
apt
e
r
5
Inst
alla
tion Cons
id
era
tions
Wiring and Installation
E
5-1-3. Distance from Reflective Surfaces
Install the F3SG-SR/PG so that it is not affected by reflective surfaces. Failure to do so
may hinder detection, resulting in serious injury.
Install the sensor system at distance D or further from highly reflective surfaces such as metallic walls,
floors, ceilings, or workpieces, as shown below.
F3SG-SR/PG (Type 4 ESPE)
5-1-3-1. F3SG-SR/PG (Type 2 ESPE)
Distance between an emitter and a
receiver (operating range L)
Allowable installation distance
D
0.3 to less than 3 m
0.13 m
3 m or more
L/2 x tan5 ° = L x 0.044 m
Distance between an emitter and a
receiver (operating range L)
Allowable installation distance
D
0.3 to less than 3 m
0.26 m
3 m or more
L/2 x tan10 ° = L x 0.089 m
L
D
D
L
D
5
5
Detection zone
Emitter
Recei
v
er
Reflecti
v
e ceiling
Reflecti
v
e floor
Emitter
Recei
v
er
Reflecti
v
e s
u
rface
L
D
D
L
D
10
10
Detection zone
Emitter
Recei
v
er
Reflecti
v
e ceiling
Reflecti
v
e floor
Emitter
Recei
v
er
Reflecti
v
e s
u
rface
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...