
i
F3SG-SR/PG
User’s Manual
Int
ro
ductio
n
E
1. The F3SG-SR/PG does not receive type approval provided by Article 44-2 of the Industrial Safety and
Health Act of Japan. When using the F3SG-SR/PG in Japan as a "safety system for pressing or shearing
machines" prescribed in Article 42 of that law, the machine control system must receive type approval.
2. The F3SG-SR/PG is electro-sensitive protective equipment (ESPE) in accordance with European Union
(EU) Machinery Directive Index Annex V, Item 2.
3. EU Declaration of Conformity
OMRON declares that the F3SG-SR/PG is in conformity with the requirements of the following EU
Directives:
Machinery Directive 2006/42/EC
EMC Directive 2014/30/EU
4. Conforming Standards
(1) European standards
EN61496-1 (Type 4 and Type 2 ESPE), EN 61496-2 (Type 4 and Type 2 AOPD), EN61508-1 through -4
(SIL 3 for Type 4 and SIL 1 for Type 2),
EN ISO 13849-1:2015 (PL e, Category 4 for Type 4 and PL c, Category 2 for Type 2)
(2) International standards
IEC61496-1 (Type 4 and Type 2 ESPE), IEC61496-2 (Type 4 and Type 2 AOPD), IEC61508-1 through -4
(SIL 3 for Type 4 and SIL 1 for Type 2),
ISO 13849-1:2015 (PL e, Category 4 for Type 4 and PL c, Category 2 for Type 2)
(3) JIS standards
JIS B 9704-1 (Type 4 and Type 2 ESPE), JIS B 9704-2 (Type 4 and Type 2 AOPD)
(4) North American standards
UL61496-1 (Type 4 and Type 2 ESPE), UL61496-2 (Type 4 and Type 2 AOPD), UL508, UL1998,
CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8
(5) Chinese standards
GB/T 4584 (Specification of active opto-electronic protective devices for presses)
(Models: F3SG-4SR
-14/-25 in the case of the ON to OFF response time not exceeding 20 ms max.)
The following configurations of the F3SG-SR are compliant with GB/T 4584.
Configurations using the F3SG-SR with detection capability of 14-mm or 25-mm dia. and 20 ms max. of
the ON to OFF response time
* Refer to
1-6-3. Calculation of Response Time of Cascaded Segments
for more information on the response time for the F3SG-SR
in cascade connection.
The F3SG-SR's with detection capability of 45-mm and 85-mm dia. are not compliant with GB/T 4584.
Refer to
1-5. Ratings and Specifications
for more information on the ratings and specifications by model.
Legislation and Standards
Detection capability
Protective height
Number
of beams
Configuration
Synchronization
method
Response Time
Adjustment
ON to OFF
response time
14-mm dia.
160 to 2000 mm
-
Single
Optical
Normal
18 ms max.
14-mm dia.
160 to 1400 mm
-
Single
Wired
Normal
17 ms max.
25-mm dia.
160 to 2480 mm
-
Single
Optical/Wired
Normal
17 ms max.
Combination of 14-mm and 25-mm
dia. in cascade connection
-
255 max.
Cascaded
Optical
Normal
18 ms max.*
Combination of 14-mm and 25-mm
dia. in cascade connection
-
140 max.
Cascaded
Wired
Normal
15 ms max.*
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...