91
F3SG-SR/PG
User’s Manual
Chapter
2
Mu
ti
ng
System Operation and Functions
E
Basic wiring diagram
2-13-3-2. Installation Example of Exit-Only Muting Mode
This is an installation example of the Exit-Only Muting mode. When using the Exit-Only Muting mode,
install the muting sensors on the hazardous side of the workpiece exit.
This can be used if a workpiece has a certain length and the hazardous side of the workpiece exit has
enough space around it.
1.
Before a workpiece passes through
All muting sensors are turned OFF and the safety function of the F3SG-SR/PG is working.
2.
MUTING started
When the muting sensors A1 and B1 are turned ON in this order, and the MUTING state is enabled. In
this state, the safety function of F3SG-SR/PG is disabled.
+24
V
DC
0
V
P
N
P
N
P
N
S1
S2
0
V
+24
V
DC
S1
S2
24
V
/0
V
(Bro
w
n)
MUTE B (Pink)
MUTE A (Gray)
0
V
/24
V
(Bl
u
e)
S1, S2: M
u
ting sensor
24
V
/0
V
(Bro
w
n)
MUTE B (Pink)
MUTE A (Gray)
0
V
/24
V
(Bl
u
e)
F3SG-SR/
F3SG-PGA-A/-L
recei
v
er,
F3SG-PGA-C
emitter/recei
v
er
F3SG-SR/
F3SG-PGA-A/-L
recei
v
er,
F3SG-PGA-C
emitter/recei
v
er
W
orkpiece
F3SG-SR/PG
A1 B1
Hazardo
u
s zone
A1 : M
u
ting sensor to
b
e connected
to m
u
ting inp
u
t A
B1 : M
u
ting sensor to
b
e connected
to m
u
ting inp
u
t B
d1: Distance
b
et
w
een A1 and B1
d2: Distance
b
et
w
een A1 and F3SG-SR/PG
V
d2
d1
W
orkpiece
F3SG-SR/PG
A1 B1
Hazardo
u
s zone
V
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...