6. Mounting and Beam Alignment
6-1. Mounting with Free-Location Brackets (F39-LGRA)
■
Dimensions (Check position)
31.4
46.35
10
10
P
D
C(Protective height)
150 max.
150 max.
F
56.5
56.5
150 max.
F
150 max.
C
3.95
2-M4
2-M4
2-M5 or M6
<Screw: M5 or M6>
2-M5 or M6
38
Free-Location Bracket
(F39-LGRA)
Free-Location Bracket
(F39-LGRA)
26.3
73
6.3
3.95
56.5
50
[ Unit : mm ]
[Backside mounting]
*1.The number of brackets required to mount either one of emitter and receiver.
*2.Mounting an emitter or receiver with one bracket is possible for the model of protective height of 0240. In this case, locate this
bracket at half the Dimension C (or at the center of the sensor length).
Refer to the user's manual for dimensions of side mounting.
Dimension C
4-digit number of the type name (Protective height)
Dimension D
C-20
Dimension P
20
Protective height (C)
Number of Free-Location Brackets *1
Dimension F
0240 to 1200
2 *2
1000 mm max.
1280 to 1920
3
1000 mm max.
Check
position
Step1
Mount
Step2
Align
beams
Step3
Mounting/Beam Alignment
Wiring
Setting
Operation check